| POST Error Messages | |
|
|
|
|
|
|
|
POST Error Messages |
|
|
|
| ||
|
|
|
|
|
| |
|
| Screen Message | Beeps* | Probable Cause | Recommended Action |
|
|
|
|
|
|
| |
|
| None | Hard drive is about to | Determine if hard drive is giving |
| |
|
| Drive Detects Imminent |
| fail. (Some hard drives | correct error message. Run the Drive | |
|
| Failure |
| have a firmware patch | Protection System test available. | |
|
|
|
| that will fix an erroneous | Apply firmware patch if applicable | |
|
|
|
| error message.) | (see | |
|
|
|
|
| www.compaq.com\support\techpu | |
|
|
|
|
| bs\customer_advisories). | |
|
|
|
|
| Back up contents and replace hard | |
|
|
|
|
| drive. | |
|
|
|
|
|
|
|
|
|
| None | Hard drive is about to | Determine if hard drive is giving | |
|
| Hard Drive Detects |
| fail. (Some hard drives | correct error message. Run the Drive | |
|
| Imminent Failure |
| have a firmware patch | Protection System test available. | |
|
|
|
| that will fix an erroneous | Apply firmware patch if applicable. | |
|
|
|
| error message.) | Back up contents and replace hard | |
|
|
|
|
| ||
|
|
|
|
| drive. | |
|
|
|
|
|
|
|
|
| 2S | Internal and external | Remove any disk controller | ||
|
| Address Assignment |
| hard drive controllers are | expansion cards. | |
|
| Conflict |
| both assigned to the | Clear CMOS. | |
|
|
|
| primary address. | Reconfigure card resources and/or | |
|
|
|
|
| ||
|
|
|
|
| run Computer Setup (F10 Setup). | |
|
|
|
|
|
|
|
|
| 2S | Internal and external | Remove any disk controller | ||
|
| Port Address |
| hard drive controllers are | expansion cards. | |
|
| Assignment Conflict |
| both assigned to the | Clear CMOS. | |
|
|
|
| primary address. | Reconfigure card resources and/or | |
|
|
|
|
| ||
|
|
|
|
| run Computer Setup (F10 Setup). | |
|
|
|
|
|
|
|
|
| None | Hard drive/format error. | Run Computer Setup | ||
|
|
|
|
| (F10 Setup). | |
|
|
|
|
| Clear CMOS. | |
|
|
|
|
| Check cables/jumper settings. | |
|
|
|
|
| Run hard drive diagnostics. | |
|
|
|
|
| Disconnect additional drives. | |
|
|
|
|
| Run the Drive Protection System test if | |
|
|
|
|
| available. | |
|
|
|
|
| Replace the hard drive. | |
|
|
|
|
|
|
|
|
| * L = Long, S = Short |
|
|
|
|
| Service Reference Guide |