Diagnostic Error Codes

Test Error Codes (Continued)

Error Code

Description

 

Recommended Action

 

 

 

XXXX-35

Invalid SCSI bus phase.

Replace the indicated device.

 

 

 

XXXX-36

Invalid SCSI bus phase.

Replace the indicated device.

 

 

 

XXXX-39

Error status from drive.

Replace the indicated device.

 

 

 

XXXX-40

Target timed out.

Replace the indicated device.

 

 

 

XXXX-41

SCSI bus stayed busy.

Replace the indicated device.

 

 

 

XXXX-42

ACK/REQ lines bad.

Replace the indicated device.

 

 

 

XXXX-43

ACK did not deassert.

Replace the indicated device.

 

 

 

XXXX-44

Parity error.

Replace the indicated device.

 

 

 

XXXX-50

Data pins bad.

Replace the indicated device.

 

 

 

XXXX-51

Data line 7 bad.

Replace the indicated device.

 

 

 

XXXX-52

MSG, C/D, and/or I/O lines

Replace the indicated device.

 

bad.

 

 

 

 

 

XXXX-53

BSY never went busy.

Replace the indicated device.

 

 

 

XXXX-54

BSY stayed busy.

Replace the indicated device.

 

 

 

XXXX-60

Controller CONFIG-1 register

Replace the indicated device.

 

bad

 

 

 

 

 

XXXX-61

Controller CONFIG-2 register

Replace the indicated device.

 

bad

 

 

 

 

 

XXXX-65

Media not unloaded.

Replace the indicated device.

 

 

 

 

XXXX-90

Fain failure.

1.

Ensure fan(s) connected.

 

 

2.

Replace nonfunctional fan(s).

 

 

 

 

XXXX-91

Over temperature.

1.

Ensure proper air flow.

 

 

2.

Perform required maintenance and

 

 

 

cleaning.

 

 

 

 

XXXX-99

Autoloader reported tapes not

1.

Install tape(s) in autoloader tape drive

 

loaded properly.

 

according to test instructions.

 

 

2.

Change autoloader magazine.

 

 

 

 

 

E–12

Service Reference Guide