INSTALLATION CODES AND STANDARDS
The HFB6 FlashBake oven must be installed in accordance with:
In the United States of America:
1.State and local codes.
2.National Electrical Code,
In Canada:
1.Local codes.
2.Canadian Electrical Code, Part 2, CSA Standard C22.1 (latest edition). Copies may be obtained from The Canadian Standard Association, 178 Rexdale Blvd., Rexdale, Ontario, Canada M9W 1R3.
ASSEMBLY
Install the upper lamp shield into the oven cavity. Be sure the shield is pushed all the way back and is lying flat in the channels. Refer to REMOVING AND INSTALLING THE TOP LAMP SHIELD, page 13.
Place the grill on the rollers.
EXHAUST DUCT INSTALLATION
A length of flexible exhaust duct may be attached to the oven to vent hot air out of the area. Attach the duct to the blower assembly (Fig. 1).
The other end of the duct can be vented into an existing hood, or to the outside in a manner consistent with local building codes.
The exhaust duct must not be less than 4" (10.1 cm) diameter, and a recommended maximum length of 6 feet (182.9 cm). The duct should be made of metal, suitable for high temperature use. Be sure there are no bends in the duct that will restrict air flow.
Aduct longer than 6 feet (182.9 cm) may require a supplementary exhaust system to ensure adequate air flow. The exhaust system must support 135 cfm.
Fan
Power Cord
Flexible Duct
(By Others)
Duct Clamp
(By Others)
Blower |
OVEN REAR
Fig. 1
– 4 –