3-13. Selecting A Location And Connecting Input Power
Y Do not move or operate unitwhere it could tip.
Y Installation must meet all Na- |
tional and Local Codes − |
have only qualified persons |
make this installation. |
Y Special installation may be |
required where gasoline or |
volatile liquids are present − |
18 in (457 mm) of space for airflow
1
8
5
=GND/PE Earth Ground
10 |
| |
7 |
| |
9 |
| |
L1 | 4 | |
L2 | ||
|
see NEC Article 511 or CEC |
Section 20. |
Y Disconnect and lockout/tag- |
out input power before con- |
necting input conductors |
from unit. |
Y Always connect green or |
green/yellow conductor to |
supply grounding terminal |
first, and never to a line ter- minal.
1 Rating Label
Supply correct input power.
2Plug
3Receptacle
Connect plug to receptacle.
4 | Black And White Input |
| Conductor (L1 And L2) |
5 | Green Or Green/Yellow |
| Grounding Conductor |
6
2
1 4
3
L2L1
230 VAC, 1
6 | Input Power Cord. |
7 | Disconnect Device (switch |
| shown in the OFF position) |
8 | Disconnect Device Grounding |
| Terminal |
9 | Disconnect Device Line |
| Terminals |
Connect green or green/yellow grounding conductor to disconnect device grounding terminal first.
Connect input conductors L1 and L2 to disconnect device line termi- nals.
10
Select type and size of
Close and secure door on discon- nect device. Remove lockout/tag- out device, and place switch in the On position.
803