3-13. Selecting A Location And Connecting Input Power
803 766-B / 802 286-E
4
2
YDo not move or operate
unitwhere it could tip.
18 in (457 mm) of
space for airflow
1
YInstallation must meet all Na-
tional and Local Codes
have only qualified persons
make this installation.
YSpecial installation may be
required where gasoline or
volatile liquids are present
see NEC Article 511 or CEC
Section 20.
YDisconnect and lockout/tag-
out input power before con-
necting input conductors
from unit.
YAlways connect green or
green/yellow conductor to
supply grounding terminal
first, and never to a line ter-
minal.
1 Rating Label
Supply correct input power.
2 Plug
3 Receptacle
Connect plug to receptacle.
4 Black And White Input
Conductor (L1 And L2)
5 Green Or Green/Yellow
Grounding Conductor
6 Input Power Cord.
7 Disconnect Device (switch
shown in the OFF position)
8 Disconnect Device Grounding
Terminal
9 Disconnect Device Line
Terminals
Connect green or green/yellow
grounding conductor to disconnect
device grounding terminal first.
Connect input conductors L1 and
L2 to disconnect device line termi-
nals.
10 Over-Current Protection
Select type and size of over-current
protection using Section 3-12
(fused disconnect switch shown).
Close and secure door on discon-
nect device. Remove lockout/tag-
out device, and place switch in the
On position.
L1
L2
230 VAC, 1
3
7
6
L1
L2
1
=GND/PE Earth Ground
5
4
8
9
10