4-4. Duty Cycle
Duty cycle is the percentage of 10
1minutes that unit can weld at rated load without overheating.
1 100% Duty Cycle
This unit is rated for continuous welding at 90 amperes CC/AC.
2 30% Duty Cycle
This unit is rated at 30% duty cycle
2(3 minutes welding, 7 minutes rest- ing) at 140 amperes CC/AC.
NOTICE − Exceeding duty cycle can damage unit and void warranty.
212 950
4-5. Generator Power Curve
The ac generator power curves show the generator power available in amperes at the receptacles.
AC Power Volts
300
250
200
150
100
50 |
|
|
|
|
|
|
0 0 | 10 | 20 | 30 | 40 | 50 | 60 |
AC Power Amperes
226 077