4-17. Adjusting Trigger Hold Actuation Time

To adjust trigger hold actuation time, proceed as follows:

1 Motor Speed Control Board PC1

2 Potentiometer R50

. Trigger hold actuation time

range is from 0 to 4 seconds.

To decrease trigger hold actuation time, use a small nonconductive

screwdriver and rotate potentiometer clockwise; to increase actuation time, rotate potentiometer counterclockwise.

Reinstall side panel.

1

Top Of PC1

2

Tools Needed:

Nonconductive

1/4 in

Ref. 801 557 / 197 716