4-5. Water-Cooled Gun Connections

2

7

6

8

3

4

5

 

Left Side

10

1

9

10

1

9

Tools Needed:

9/16 in

1 Gun Control Cable

Insert plug into Gun Control receptacle, and tighten threaded collar.

2Gas Hose

3Reed Relay

4Weld Cable

5Weld Cable Terminal In Feeder

Route weld cable from welding power source through reed relay to weld cable terminal in feeder and connect to weld cable terminal.

6Gun Connector

7Gun Securing Knob

8Gun Connector Block

Loosen gun securing knob, and insert gun connector through Wire opening until it bottoms against block. Tighten knob. Close and latch door.

9 Water In Hose

Connect to Water In fitting on feeder (left-hand threads).

10 Water Out Hose

Connect to Water Out fitting on feeder (left-hand threads)

Close and latch door.

Ref. 801 577-A / 801 563 / Ref. 151 666-A