5-3. Plasma Cutting System Practices

.A complete Parts List is available at www.HobartWelders.com

5-3. Plasma Cutting System Practices

Y The pilot arc starts immediately when trigger is pressed.

Always connect work clamp to a clean,

DO NOT start pilot arc without cutting as this

paint-free location on workpiece, as close to

shortens the life of the tip and electrode.

cutting area as possible.

 

.Do not connect work clamp to the portion of the workpiece that will fall when cut.

90°Manual background

°

Sparks should pass through the workpiece

If sparks flare back from surface, this

Maintain approximately a 90 angle to the

and out the bottom when cutting.

usually is an indication that travel

workpiece surface for proper cutting results.

 

 

speed is too fast.

Wt

 

 

DO NOT put pressure on shield when

Pulling rather than pushing the torch

drag cutting; instead, slide shield along

makes cutting easier. Use a proper guide

the surface for proper cutting results.

or template for accurate cutting operations.

Ref 803 915-A / Ref. 804 848-A