operation

Starting the engine

See Figures 11 - 13.

NOTE:  If location of generator is not level, the unit may not start or may shut down during operation.

Unplug all loads from the generator.

Turn the fuel valve to the ON position.

Move the choke lever right to the START position.

NOTE:  If engine is warm or the temperature is above

50˚F, move the choke lever left to the RUN position.

Put the engine switch in the ON ( I ) position.

Pull the recoil starting grip until the engine runs (a maxi- mum of 6 times).

NOTE:  Do not allow the grip to snap back after starting; return it gently to its original place.

Allow the engine to run for 30 seconds, then move the choke lever left to the RUN position.

Stopping the engine

See Figures 11 - 12.

To stop the engine under normal operating conditions:

Remove any load from the generator.

Turn the fuel valve to the OFF position.

Put the engine switch in the OFF ( O ) position.

To stop the engine in an emergency situation:

Put the engine switch in the OFF ( O ) position.

understanding the digital display

See Figure 14.

The digital display shows AC voltage output, frequency, and the total number of hours the generator has been used. To cycle through these displays, depress the select button. The indicators below the digital display will light in sequence to show which type of information is being displayed.

If an alarm condition exists, the button associated with the alarm will blink.

AC voltage: The AC voltage indicator will blink when the output voltage exceeds the rated voltage more than 10%. The light will stop blinking when the voltage returns to within the 10% range.

Frequency: The frequency indicator will blink when the rated frequency is more than 5%. Once the frequency has returned to within the 5% range, the indicator will stop blinking.

Low engine lubricant: The low engine lubricant light will blink and the engine will automatically shut off whenever the lubricant level in the engine becomes low. The engine may not be restarted until sufficient engine oil as been added to the generator.

NOTE: It is normal for the indicator lights to illuminate and/or blink each time the engine is started. Once the engine warms up, the lights should default to the pattern above.

Page 14 — English

Page 18
Image 18
Homelite HGCA3000 Starting the engine, Stopping the engine, Understanding the digital display, See Figures 11, English