TrueSTEAM Humidification System
17 69-2285EFS—03
maIntenancemaIntenance8. Replace inline filter at least once per season. Turn water supply off before replacing.
Press down filter
collar ring and
pull out 1/4 in.
water line from
each side.
Insert 1/4 in. lines into
new filter. Apply modest
pull to ensure a tight fit.
M28697
M27411
9. Onceclean,reattachtankbysecuringthelatch.Engage thewhite
watervalvetothetank’sblackspool,and“Lock”theshut-off valve.
The “Press Reset” light will blink at start-up. Push the RESET button
to ready the humidifier.
10.
•Clearanydustfromtheventilationholesinthehumidifier’scover.
•Clearanydebrisfromthewaterdraintube.
•Makesurethewatertankgasketsealisseatedproperly inthe
humidifierbase,andisingoodcondition(no cracksortears)before
reattaching the humidifier water tank.
•Checkthatthehumidifierisstillmountedlevel.
M28698
automatic end of season shutdown
TrueSTEAM has the intelligence to empty the tank when humidity is not needed for an extended
period.After48hoursofinactivity,TrueSTEAMwilldrainandremainemptyuntilhumidityis
needed again. This prevents water from stagnating within the tank. The tank will refill with water
upon next humidity call.
extended Vacation
It is recommended you turn off the humidifier’s water supply and turn off the humidity control for
extendedleaves.Whenyoureturn,turnon thehumidifierwatersupplyandresetthehumidity
control to a comfortable position.