Installation

2.Configure the following behavior settings:

ALARM OUT

Choose to configure a specific alarm output.

 

 

OPERATION

Enable/disable the selected alarm output.

 

 

MODE

Select from TRANSPARENT (the output is active only when the

 

trigger criteria are present) or LATCHED (the output is active for

 

a set period of time after a trigger).

 

 

DURATION

In LATCHED mode, this is the time that the alarm output remains

 

active after it has been triggered.

 

 

TYPE

Select from HIGH (0V to +5V when activated) or LOW (+5V to 0V

 

when activated).

 

 

HDD EVENT

Determines whether a hard drive event triggers the alarm output.

 

 

3.Configure the following action settings:

ALARM

Configure whether the alarm inputs trigger the alarm output.

 

 

VIDEO LOSS

Configure whether video loss on any of the selected channels

 

triggers the alarm output.

 

 

MOTION

Configure whether motion detection on any of the selected

 

channel triggers the alarm output.

 

 

Note Remember to select APPLY and click to save all settings before exiting these menus.

Configuring Buzzer Out Settings

1.Click BUZZER OUT on the left side of the EVENT/SENSOR window. The BUZZER OUT setup menu appears.

60