Diagnostic Indicator Display

 

Error

 

Description

 

Code

 

 

 

 

COPROCESSOR COMMUNICATION ERROR – The main microprocessor is not communicating with the interface coprocessor. The interface coprocessor may be in a fault condition with the host

09or just not able to respond. This error may appear when the scanner is configured for USB or RS485 interface applications or during an attempt to update the interface software through the flash utility. The unit should be repaired at an authorized service center.

SWITCH ERROR – The switch used for volume selection or sleep mode is detected in error (always

11closed). The condition is self-correcting if possible. If the error persists, return the unit for repair at an authorized service center. The scanning operation can continue with this error active.

12Reserved

SCALE ERROR – Single Cable Scanner/Scales Only.

The scanner does not communicate with the scale. Make sure there is nothing plugged into the

13‘Scale RS232 to Host’ port. If there is a disconnected cable, it may be causing the communication error. If there is still no communication between the scanner and scale, return the unit to authorized service center for repair.

14SCALE RETURN TO ZERO ERROR – The scale did not return to zero between scale weight requests if the zero checking function is enabled. The scale will need to be re-zeroed.

LASER #1 (VERTICAL) ERROR – The laser in the vertical scanning subsystem denotes a failure.

21The scanner will try three times to correct the laser operation. If the laser error persists, the vertical scanning subsystem will be shut down and this error code will remain on the Diagnostic Indicators.

LASER #2 (RIGHT HORIZONTAL) ERROR – The right laser in the horizontal scanning subsystem

22denotes a failure. The scanner will try three times to correct the laser operation. If the laser error persists, and the left horizontal laser (#3) is also in error, the horizontal scanning subsystem will be shut down and this error code will remain on the Diagnostic Indicators.

LASER #3 (LEFT HORIZONTAL) ERROR – The left laser in the horizontal scanning subsystem

23denotes a failure. The scanner will try three times to correct the laser operation. If the laser error persists, and the right horizontal laser (#2) is also in error, the horizontal scanning subsystem will be shut down and this error code will remain on the Diagnostic Indicators.

LASER #1 (VERTICAL) HIGH CURRENT WARNING – The laser in the vertical scanning

24subsystem is drawing excessive current. This could be a warning for a future total failure. Have the unit checked at an authorized service center when convenient.

37