Symptom | Possible Cause(s) | Solution | |
RS232 Only |
|
| |
| The com port at the host |
| |
| is not working or is not |
| |
The unit powers up OK | configured properly. | Check to make sure that the baud rate and parity of | |
| |||
and scans OK but does | The cable is not | the scanner and the communication port match and | |
not communicate | connected to the proper | the program is looking for RS232 data. | |
properly to the host. | com port. |
| |
| The com port is not |
| |
| operating properly. |
| |
|
|
| |
The host is receiving | The scanner and host | Check that the scanner and the host are configured | |
data but the data does | may not be configured | ||
for the same interface. | |||
not look correct. | for the same interface. | ||
| |||
|
|
| |
Characters are being | The intercharacter delay | Add some intercharacter delay to the transmitted | |
needs to be added to the | output by using the MetroSelect Configuration Guide | ||
dropped. | |||
transmitted output. | (PN | ||
| |||
|
|
| |
Aux Port Operation With Any Interface |
| ||
|
|
| |
The secondary scanner |
| Refer to the user’s guide provided with the secondary | |
is not functioning. |
| scanner. | |
|
|
| |
| The secondary scanner |
| |
| cable may not be | Ensure that the secondary scanner is connected to | |
| connected to the proper | the MS2420 com port marked “Aux” port. | |
| port on the MS2420. |
| |
The secondary scanner |
|
| |
| * The MS2420 series must be configured to enable | ||
powers up but data is |
| the auxiliary port. | |
not relayed to the host. | The auxiliary com port |
| |
| may not be operating |
| |
| properly. | The auxiliary input port’s data format must match the | |
|
| ||
|
| main output format of the secondary scanner. | |
|
|
|
*Refer to the MS2xxx Stratos Series Configuration Addendum (PN
63