34-ST-03-64 Page 19
Ordering Information
Mounting Bracket
The angle mounting bracket is available in either
Indicating Meter
(Options ME and SM)
Two integral meter options are available. An analog meter (option ME) is available with a 0 to 100% linear scale. The Smart Meter (option SM) provides an LCD display for both analog and digital output and can be configured to display pressure in
HART® Protocol Compatibility (Options HC and H6)
Optional electronics modules for the ST 3000 provides HART Protocol compatibility in either HART 5.x or 6.x formats. Transmitters with a HART Option are compatible with any HART enabled system that provides 5.x or 6.x format support.
FOUNDATION Fieldbus
(Option FF)
Equips transmitter with FF protocol for use in 31.25 kbit/s FF networks. See document
SIL2/SIL3 Certification (Option SL)
This ST 3000 product is available for use with safety systems. With the SL option, we are fully certified to SIL 2 capability for single transmitters and SIL 3 capability for multiple transmitter use through TÜV Nord Sys Tec GmbH & Co. KG. We are in compliance with the following SIL standards:
IEC
IEC
IEC
NAMUR NE43 Compliance (Option NE)
This option provides software the meets the NAMUR NE43 requirements for failsafe software. Transmitter failure information is generated when the measuring information is no longer valid. Transmitter failure values are:
≤3.6 mA and ≥ 21.0 mA. The normal ST 3000 ranges are ≤ 3.8 mA and ≥ 20.5 mA.
Lightning Protection
(Option LP)
A terminal block with circuitry that protects the transmitter from transient surges induced by nearby lightning strikes is available.
Indicator Configuration (Option CI)
Provides custom configuration of Smart Meters
Tagging (Option TG)
Up to 30 characters can be added on the stainless steel nameplate mounted on the transmitter’s electronics housing at no extra cost. Note that a separate nameplate on the meter body contains the serial number and
Transmitter Configuration (Option TC)
The factory can configure the transmitter linear/square root extraction, damping time, LRV, URV and mode (analog/digital) and enter an ID tag of up to eight characters and scratchpad information as specified.
Custom Calibration and ID in Memory (Option CC)
The factory can calibrate any range within the scope of the transmitter’s range and enter an ID tag of up to eight characters in the transmitter’s memory.
Contact your nearest Honeywell sales office, or
In the U.S.:
Honeywell
Industrial Automation & Control
16404 North Black Canyon Hwy.
Phoenix, AZ 85053
In Canada:
The Honeywell Centre
155 Gordon Baker Rd.
North York, Ontario M2H 3N7
In Latin America:
Honeywell Inc.
480 Sawgrass Corporate Parkway,
Suite 200
Sunrise, FL 33325
(954)
In Europe and Africa: Honeywell S. A.
Avenue du Bourget 1
1140 Brussels, Belgium
In Eastern Europe: Honeywell Praha, s.r.o. Budejovicka 1 140 21 Prague 4,
Czech Republic
In the Middle East:
Honeywell Middle East Ltd.
Khalifa Street,
Sheikh Faisal Building
Abu Dhabi, U. A. E.
In Asia:
Honeywell Asia Pacific Inc.
Honeywell Building,
17 Changi Business Park Central 1
Singapore 486073
Republic of Singapore
In the Pacific:
Honeywell Pty Ltd.
5 Thomas Holt Drive
North Ryde NSW Australia 2113
(61 2) 9353 7000
In Japan:
Honeywell K.K.
Or, visit Honeywell on the World Wide Web at: http://www.honeywell.com
Specifications are subject to change
without notice