34-ST-03-64 Page 7

Performance Under Rated Conditions * - Model STR13D (0-5 to 0-100 psid)

Parameter

Upper Range Limit **

psid

 

bar

 

 

Minimum Span

psid

 

bar

 

 

Turndown Ratio

 

Zero Elevation and Suppression

Accuracy (Reference – Includes combined effects of linearity, hysteresis, and repeatability)

Stated accuracy does not apply for models with 2.9 inch diameter remote seal diaphragms.

Accuracy includes residual error after averaging successive readings.

For FOUNDATION Fieldbus use Digital Mode specifications. For HART use Analog Mode specifications.

Combined Zero and Span Temperature Effect per 28°C (50°F) ***

Description

100

7

5

0.35

20 to 1

No limit except minimum span within –18% and +100% of URL. Specifications valid from –5% to 100% of URL.

In Analog Mode: ±0.1% of calibrated span or upper range value (URV), whichever is greater, terminal based.

For URV below reference point (30 psi), accuracy equals:

 

30 psi

 

2 bar

±0.05 + 0.05 (

 

) or

±0.05 + 0.05 (

 

) in % of span

span psi

span bar

In Digital Mode: ±0.075% of calibrated span or upper range value (URV), whichever is greater, terminal based.

For URV below reference point (30 psi), accuracy equals:

 

30 psi

 

2 bar

±0.025 + 0.05 (

 

) or ±0.025 + 0.05

(

 

) in % of span

span psi

span bar

In Analog Mode: ±0.33% of span.

For URV below reference point (60 psi), effect equals:

±0.05 + 0.2

60 psi

4 bar

In % span

span psi

or ±0.05 + 0.28

span bar

 

 

 

 

 

 

In Digital Mode: ±0.305% of span.

For URV below reference point (60 psi), effect equals:

 

60 psi

4 bar

 

±0.025 + 0.25

span psi

or ±0.025 + 0.28

span bar

In % span

*Performance specifications are based on reference conditions of 25°C (77°F), zero (0) static pressure, 10 to 55% RH, and 316L Stainless Steel barrier diaphragm.

**Transmitter URL limit or maximum seal pressure rating, whichever is lower.

***Specification applies to transmitters with 2 seals only. Apply 1.5 times factor to temperature effect for capillary lengths greater than 10 feet.

Page 7