TABLE II - SEALS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

34-ST-03-64

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 21

TABLE II - SEALS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Format for Seal Selection:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Specify 12 characters

 

 

_ _ _ _ _ _ _ _ _ _ _ _

 

 

 

 

 

 

 

14A

 

 

 

 

 

 

 

 

 

 

 

 

12D & 13D

 

 

 

 

14G&17G

 

 

Common

 

 

 

Required Seal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: The first 3 characters are common to all seals.

 

 

 

 

 

 

 

 

 

When selecting required seal, you must specify

Selection

 

 

 

 

 

only the 9 selections within the required seal.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No Fill Fluid

 

 

0 _ _ _ _ _ _ _ _ _ _ _

3

3

3

 

 

 

 

 

 

 

 

Silicone (DC 200)

 

 

1 _ _ _ _ _ _ _ _ _ _ _

 

Secondary Fill

 

 

 

 

 

 

 

 

CTFE

 

 

2 _ _ _ _ _ _ _ _ _ _ _

 

 

 

 

 

 

 

Silicone (DC 704)

 

 

3 _ _ _ _ _ _ _ _ _ _ _

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Neobee(M20) **

 

 

4 _ _ _ _ _ _ _ _ _ _ _

 

 

 

 

 

 

 

 

Syltherm 800 ***

 

 

5 _ _ _ _ _ _ _ _ _ _ _

 

 

 

 

 

 

No Capillary, No Nipple

_ 0 _ _ _ _ _ _ _ _ _ _

3

3

3

 

 

 

 

 

5 feet

 

1.5 m

 

 

 

_ A _ _ _ _ _ _ _ _ _ _

 

 

 

 

 

10 feet

 

3.0 m

 

 

 

_ B _ _ _ _ _ _ _ _ _ _

 

 

 

 

 

15 feet

 

4.5 m

 

 

SS Armor

_ C _ _ _ _ _ _ _ _ _ _

 

 

 

 

 

20 feet

 

6.1 m

 

 

_ D _ _ _ _ _ _ _ _ _ _

 

 

 

 

 

 

 

 

 

 

Connection of

 

 

 

25 feet

 

7.5 m

 

 

 

_ E _ _ _ _ _ _ _ _ _ _

 

Capillary

35 feet

 

10.7 m

 

 

 

_ F _ _ _ _ _ _ _ _ _ _

 

Remote Seal to

 

 

 

 

 

Length

5 feet

 

1.5 m

 

 

 

_ G _ _ _ _ _ _ _ _ _ _

 

Meter Body

 

 

 

 

 

 

 

 

10 feet

 

3.0 m

 

 

 

_ H _ _ _ _ _ _ _ _ _ _

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15 feet

 

4.5 m

 

PVC Coated SS

_ J _ _ _ _ _ _ _ _ _ _

 

 

 

 

 

20 feet

 

6.1 m

 

 

Armor

_ K _ _ _ _ _ _ _ _ _ _

 

 

 

 

 

25 feet

 

7.5 m

 

 

 

_ L _ _ _ _ _ _ _ _ _ _

 

 

 

 

 

35 feet

 

10.7 m

 

 

 

_ M _ _ _ _ _ _ _ _ _ _

 

 

2 inch long

SS nipple

close-coupled

 

 

 

_ 2 _ _ _ _ _ _ _ _ _ _

z

z

z

 

No Selection

 

 

 

 

 

 

 

 

 

 

 

 

 

_ _ 0 _ _ _ _ _ _ _ _ _

 

No Seal Attached to Core Transmitter

 

 

 

 

 

 

_ _ _ 0 0 0 0 0 0 0 0 0

3

3

3

 

 

Diaphragm

Flange

 

 

Flange Pressure

Selection

 

 

 

 

 

 

Diameter

Size

 

 

Rating *

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ANSI Class 150

_ _ _ AFA _ _ _ _ _ _

 

 

3.5"

 

 

3"

 

 

 

ANSI Class 300

_ _ _ AFC _ _ _ _ _ _

 

 

 

 

 

 

 

 

 

 

 

DIN DN80-PN40

_ _ _ AFM _ _ _ _ _ _

 

 

 

 

 

 

 

 

 

 

Diaphragm

 

Upper Insert

Selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

316L SS

 

316 SS

_ _ _ _ _ _ AA _ _ _ _

 

 

Wetted Material

 

Hastelloy C

 

316 SS

_ _ _ _ _ _ AB _ _ _ _

 

 

 

Hastelloy C

 

Hastelloy C

_ _ _ _ _ _ AC _ _ _ _

 

 

 

 

 

 

 

 

 

 

 

 

Flush Flanged

 

 

 

 

 

 

 

 

Monel

 

Monel

_ _ _ _ _ _ AE _ _ _ _

 

Seal

 

 

 

 

 

 

 

 

Tantalum

 

316 SS

_ _ _ _ _ _ AF _ _ _ _

1

1

1

 

 

Non-Wetted Material

 

 

CS (Nickel Plated)

_ _ _ _ _ _ _ _ 1 _ _ _

 

 

(upper)

 

 

316 SS

_ _ _ _ _ _ _ _ 2 _ _ _

 

 

Seal-Capillary

 

 

Center Seal

_ _ _ _ _ _ _ _ _ 1 _ _

 

 

Connection

 

 

Side Seal

_ _ _ _ _ _ _ _ _ 2 _ _

9

9

9

 

 

Calibration Rings

 

 

 

 

None

_ _ _ _ _ _ _ _ _ _ A _

 

 

 

 

 

 

 

 

 

 

 

316 SS

_ _ _ _ _ _ _ _ _ _ B _

5

5

5

 

 

 

 

 

 

 

 

 

 

 

Hastelloy C

_ _ _ _ _ _ _ _ _ _ C _

5

5

5

 

 

 

 

 

 

 

 

 

 

 

 

Monel

_ _ _ _ _ _ _ _ _ _ D _

5

5

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table II continued next page