| Page 27 | ||
|
|
|
| STR14A |
|
| ||
TABLE III - OPTIONS | STR12D & 13D |
|
|
| 14G & 17G | |||
|
|
| ||||||
|
|
|
|
|
|
| ||
Communication Options (Must choose a communications option) |
|
|
|
|
|
|
| |
Analog only (can be configured using appropriate Honeywell DE tool) | AN | ● | ● | ● |
|
| ||
DE Protocol communications | DE | ● | ● | ● |
|
| ||
HART 5.x Protocol compatible electronics | HC | e | e | e |
| b | ||
HART 6.x Protocol compatible electronics | H6 | e | e | e |
|
| ||
FOUNDATION Fieldbus Communications | FF | r | r | r |
|
| ||
Indicating Meter Options |
|
|
|
|
|
|
| |
Analog Meter | ME | ● | ● | ● |
|
| ||
b | ||||||||
Smart Meter | SM | ● | ● | ● | ||||
|
| |||||||
Custom Configuration of Smart Meter | CI | f | f | f |
|
| ||
Local Zero & Span | ZS | m |
| m |
| b | ||
|
| |||||||
Local Zero | LZ | x |
| x |
| |||
|
| |||||||
|
|
| ||||||
Transmitter Housing & Electronics Options |
|
|
|
|
|
|
| |
NAMUR Failsafe Software | NE | 15 | 15 | 15 |
|
| ||
SIL 2 - TÜV Certified transmitter (requires HC or H6 and WP options) | SL | 14 | 14 | 14 |
|
| ||
Lightning Protection | LP | ● | ● | ● |
|
| ||
Custom Calibration and I.D. in Memory | CC | ● | ● | ● |
|
| ||
Transmitter Configuration - | TC | 15 | 15 | 15 |
|
| ||
Transmitter Configuration - (Fieldbus) | FC | 21 | 21 | 21 |
|
| ||
Write Protection (Delivered in the "enabled" position) | WP | ● | ● | ● |
|
| ||
| b | |||||||
Write Protection (Delivered in the "disabled" position) | WX | ● | ● | ● |
| |||
|
| |||||||
316 SS Electronics Housing - with M20 Conduit Connections | SH | n | n | n |
|
| ||
1/2" NPT to M20 316 SS Conduit Adapter (BASEEFA EEx d IIC) | A1 | n | n | n |
| b | ||
1/2" NPT to 3/4" NPT 316 SS Conduit Adapter | A2 | u | u | u |
| |||
Stainless Steel Housing with M20 to 1/2" NPT 316 SS Conduit | A3 | i | i | i |
|
| ||
Adapter (use for FM and CSA Approvals) |
|
| ||||||
|
|
|
|
|
|
| ||
Stainless Steel Customer | TG | ● | ● | ● |
|
| ||
b | ||||||||
(4 lines, 28 characters per line, customer supplied information) | ||||||||
|
|
|
|
|
|
| ||
Stainless Steel Customer | TB | ● | ● | ● |
|
| ||
End Cap Live Circuit Warning Label in Spanish (only with ATEX 3D) | SP | a | a | a |
| b | ||
End Cap Live Circuit Warning Label in Portuguese (only with ATEX 3D) | PG | a | a | a |
| |||
End Cap Live Circuit Warning Label in Italian (only with ATEX 3D) | TL | a | a | a |
|
| ||
End Cap Live Circuit Warning Label in German (only with ATEX 3D) | GE | a | a | a |
|
| ||
Meter Body Options (Seal bolt material depends on Transmitter bolt material) |
|
|
|
|
|
|
| |
A286 SS (NACE) Bolts and 304 SS (NACE) Nuts for Heads | CR | ● | ● |
|
| b | ||
316 SS Bolts and 316 SS Nuts for Process Heads | SS | ● |
|
|
| |||
B7M Bolts and Nuts for Process Heads | B7 | ● |
|
|
|
| ||
Remote Seal Options |
|
|
|
|
|
|
| |
Gold Plated Seal Diaphragm (1 Seal) | G1 | j | j | j |
|
| ||
Gold Plated Seal Diaphragm (2 Seals) | G2 | j |
|
|
| b | ||
Teflon Coated Seal Diaphragm (1 Seal) - only for | N1 | j | j | j |
| |||
Teflon Coated Seal Diaphragms(2 Seals) - only for | N2 | j |
|
|
|
| ||
Transmitter Mounting Brackets Options |
|
|
|
|
|
|
| |
Mounting Bracket - Carbon Steel | MB | ● | ● | ● |
| b | ||
Mounting Bracket - 304 SS | SB | ● | ● | ● |
| |||
Flat Mounting Bracket | FB | ● | ● | ● |
|
| ||
Services/Certificates Options |
|
|
|
|
|
|
| |
Users Manual Paper Copy (Standard, HC/H6 or FF ships accordingly) | UM | ● | ● | ● |
|
| ||
Clean Transmitter for Oxygen or Chlorine Service with Certificate | 0X | h | h | h |
|
| ||
TP | ● | ● | ● |
|
| |||
Calibration Test Report and Certificate of Conformance (F3399) | F1 | ● | ● | ● |
| b | ||
| ||||||||
Certificate of Conformance (F3391) | F3 | ● | ● | ● |
| |||
|
| |||||||
Certificate of Origin (F0195) | F5 | ● | ● | ● |
|
| ||
FMEDA Certificate (SIL 1) (FC33321) | F6 | ● | ● | ● |
| b | ||
| ||||||||
SIL Certificate (SIL 2/3) (FC33337) | FE | 22 | 22 | 22 |
| |||
|
| |||||||
NACE Certificate | F7 | ● | ● | ● |
| b | ||
NACE Certificate | FG | o | o | ● |
| |||
NACE Certificate (F0198) for all welded meter bodies only | F8 | 16 |
|
|
|
| ||
Marine Type Approvals (DNV, ABS, BV, KR & LR) | MT | 2 | 2 | 2 |
|
|