34-ST-03-64

 

 

 

 

 

 

Page 27

 

 

 

 

STR14A

 

 

TABLE III - OPTIONS

STR12D & 13D

 

 

 

14G & 17G

 

 

 

 

 

 

 

 

 

 

Communication Options (Must choose a communications option)

 

 

 

 

 

 

 

Analog only (can be configured using appropriate Honeywell DE tool)

AN

 

 

DE Protocol communications

DE

 

 

HART 5.x Protocol compatible electronics

HC

e

e

e

 

b

HART 6.x Protocol compatible electronics

H6

e

e

e

 

 

FOUNDATION Fieldbus Communications

FF

r

r

r

 

 

Indicating Meter Options

 

 

 

 

 

 

 

Analog Meter (0-100 Even 0-10 Square Root)

ME

 

 

b

Smart Meter

SM

 

 

Custom Configuration of Smart Meter

CI

f

f

f

 

 

Local Zero & Span

ZS

m

 

m

 

b

 

 

Local Zero

LZ

x

 

x

 

 

 

 

 

 

Transmitter Housing & Electronics Options

 

 

 

 

 

 

 

NAMUR Failsafe Software

NE

15

15

15

 

 

SIL 2 - TÜV Certified transmitter (requires HC or H6 and WP options)

SL

14

14

14

 

 

Lightning Protection

LP

 

 

Custom Calibration and I.D. in Memory

CC

 

 

Transmitter Configuration - (non-Fieldbus)

TC

15

15

15

 

 

Transmitter Configuration - (Fieldbus)

FC

21

21

21

 

 

Write Protection (Delivered in the "enabled" position)

WP

 

 

 

b

Write Protection (Delivered in the "disabled" position)

WX

 

 

 

316 SS Electronics Housing - with M20 Conduit Connections

SH

n

n

n

 

 

1/2" NPT to M20 316 SS Conduit Adapter (BASEEFA EEx d IIC)

A1

n

n

n

 

b

1/2" NPT to 3/4" NPT 316 SS Conduit Adapter

A2

u

u

u

 

Stainless Steel Housing with M20 to 1/2" NPT 316 SS Conduit

A3

i

i

i

 

 

Adapter (use for FM and CSA Approvals)

 

 

 

 

 

 

 

 

 

Stainless Steel Customer Wired-On Tag

TG

 

 

b

(4 lines, 28 characters per line, customer supplied information)

 

 

 

 

 

 

 

Stainless Steel Customer Wired-On Tag (blank)

TB

 

 

End Cap Live Circuit Warning Label in Spanish (only with ATEX 3D)

SP

a

a

a

 

b

End Cap Live Circuit Warning Label in Portuguese (only with ATEX 3D)

PG

a

a

a

 

End Cap Live Circuit Warning Label in Italian (only with ATEX 3D)

TL

a

a

a

 

 

End Cap Live Circuit Warning Label in German (only with ATEX 3D)

GE

a

a

a

 

 

Meter Body Options (Seal bolt material depends on Transmitter bolt material)

 

 

 

 

 

 

 

A286 SS (NACE) Bolts and 304 SS (NACE) Nuts for Heads

CR

 

 

b

316 SS Bolts and 316 SS Nuts for Process Heads

SS

 

 

 

B7M Bolts and Nuts for Process Heads

B7

 

 

 

 

Remote Seal Options

 

 

 

 

 

 

 

Gold Plated Seal Diaphragm (1 Seal)

G1

j

j

j

 

 

Gold Plated Seal Diaphragm (2 Seals)

G2

j

 

 

 

b

Teflon Coated Seal Diaphragm (1 Seal) - only for anti-sticking

N1

j

j

j

 

Teflon Coated Seal Diaphragms(2 Seals) - only for anti-sticking

N2

j

 

 

 

 

Transmitter Mounting Brackets Options

 

 

 

 

 

 

 

Mounting Bracket - Carbon Steel

MB

 

b

Mounting Bracket - 304 SS

SB

 

Flat Mounting Bracket

FB

 

 

Services/Certificates Options

 

 

 

 

 

 

 

Users Manual Paper Copy (Standard, HC/H6 or FF ships accordingly)

UM

 

 

Clean Transmitter for Oxygen or Chlorine Service with Certificate

0X

h

h

h

 

 

Over-Pressure Leak Test with F3392 Certificate

TP

 

 

Calibration Test Report and Certificate of Conformance (F3399)

F1

 

b

 

Certificate of Conformance (F3391)

F3

 

 

 

Certificate of Origin (F0195)

F5

 

 

FMEDA Certificate (SIL 1) (FC33321)

F6

 

b

 

SIL Certificate (SIL 2/3) (FC33337)

FE

22

22

22

 

 

 

NACE Certificate (Process-Wetted & Non-Process Wetted) (FC33339)

F7

 

b

NACE Certificate (Process-Wetted only) (FC33338)

FG

o

o

 

NACE Certificate (F0198) for all welded meter bodies only

F8

16

 

 

 

 

Marine Type Approvals (DNV, ABS, BV, KR & LR)

MT

2

2

2

 

 

Page 27