34-ST-03-64 Page 22

 

 

 

 

 

 

 

STR14A

 

 

 

STR12D & 13D

 

 

 

 

14G & 17G

 

 

 

 

 

 

 

TABLE II - SEALS (continued)

 

Selection

 

 

 

 

 

 

 

 

 

 

 

Flush Flanged

Flushing

None

_ _ _ _ _ _ _ _ _ _ _ 0

 

Connections

One 1/4" with plastic plug

_ _ _ _ _ _ _ _ _ _ _ H

6

6

6

 

Seal

and Plugs****

One 1/4" with metal plug

_ _ _ _ _ _ _ _ _ _ _ J

6

6

6

 

 

 

 

(Metal plug material

Two 1/4" with plastic plugs

_ _ _ _ _ _ _ _ _ _ _ M

6

6

6

 

 

will be the same as

Two 1/4" with metal plugs

_ _ _ _ _ _ _ _ _ _ _ N

6

6

6

 

 

Cal. ring material if

One 1/2" with plastic plug

_ _ _ _ _ _ _ _ _ _ _ P

6

6

6

 

 

metal plug is chosen -

One 1/2" with metal plug

_ _ _ _ _ _ _ _ _ _ _ Q

6

6

6

 

 

SS Plug for CS Lower)

Two 1/2" with plastic plugs

_ _ _ _ _ _ _ _ _ _ _ R

6

6

6

 

 

 

Two 1/2" with metal plugs

_ _ _ _ _ _ _ _ _ _ _ S

6

6

6

 

Table II continued below

*Standard facing 125-250 AARH RF (raised face) serrated surface finish. ** Limited vacuum availability.

*** Minimum static pressure requirement. No vacuum allowed. See Specifications Figure 15.

**** Plastic Plugs are TEMPORARY ONLY to protect threads and MUST be REMOVED before installation a Tantalum Upper insert has Tantalum wetted parts and 316 SS or CS non-wetted parts

Note: Remote seal system pressure rating is body rating or seal rating, whichever is less.

 

 

 

 

 

STR12D & 13D

 

STR14A

 

 

 

 

 

 

 

 

14G & 17G

TABLE II - SEALS (continued)

 

 

Selection

 

 

 

 

 

Diaphragm

Flange

Flange

Const. - See

Construction - See Spec.

 

 

 

 

 

Pressure

Spec. Figure 34-

 

 

 

 

 

Diameter

Size

Figure 34-ST-03-64

 

 

 

 

 

Rating *

ST-03-64

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1"

ANSI 150

22

_ _ _ BCA _ _ _ _ _ _

t

4

 

 

 

ANSI 300

22

_ _ _ BCC _ _ _ _ _ _

t

4

 

 

 

 

 

 

 

1-1/2"

ANSI 150

22

_ _ _ BGA _ _ _ _ _ _

t

4

 

 

 

ANSI 300

22

_ _ _ BGC _ _ _ _ _ _

t

4

 

 

2.4"

 

 

 

2"

ANSI 150

22

_ _ _ BDA _ _ _ _ _ _

t

4

 

 

 

 

 

 

ANSI 300

22

_ _ _ BDC _ _ _ _ _ _

t

4

 

 

 

 

 

 

 

3"

ANSI 150

22

_ _ _ BFA _ _ _ _ _ _

t

4

 

 

 

ANSI 300

22

_ _ _ BFC _ _ _ _ _ _

t

4

 

 

 

 

 

 

 

1/2"

ANSI 150

23

_ _ _ CAA _ _ _ _ _ _

 

 

 

1"

ANSI 150

23

_ _ _ CCA _ _ _ _ _ _

 

 

 

ANSI 300

23

_ _ _ CCC _ _ _ _ _ _

 

Flush Flanged

2.9"

 

 

1-1/2"

ANSI 150

22

_ _ _ CGA _ _ _ _ _ _

 

Seal with Lower

 

ANSI 300

22

_ _ _ CGC _ _ _ _ _ _

 

 

 

 

 

 

2"

ANSI 150

22

_ _ _ CDA _ _ _ _ _ _

 

 

 

ANSI 300

22

_ _ _ CDC _ _ _ _ _ _

 

 

 

 

 

 

 

1/2"

ANSI 150

22

_ _ _ DAA _ _ _ _ _ _

 

 

 

1"

ANSI 150

23

_ _ _ DCA _ _ _ _ _ _

 

 

 

ANSI 300

23

_ _ _ DCC _ _ _ _ _ _

 

 

 

 

 

 

4.1"

1-1/2"

ANSI 150

23

_ _ _ DGA _ _ _ _ _ _

 

 

ANSI 300

23

_ _ _ DGC _ _ _ _ _ _

 

 

 

 

 

 

2"

ANSI 150

23

_ _ _ DDA _ _ _ _ _ _

 

 

 

ANSI 300

22

_ _ _ DDC _ _ _ _ _ _

 

 

 

 

 

 

 

3"

ANSI 150

22

_ _ _ DFA _ _ _ _ _ _

 

 

 

ANSI 300

22

_ _ _ DFC _ _ _ _ _ _

 

 

 

 

 

Table II continued next page

*Standard facing 125-250 AARH RF (raised face) serrated finish.

**Plastic Plugs are TEMPORARY ONLY to protect threads and MUST be REMOVED before installation Note: Remote seal system pressure rating is body rating or seal rating, whichever is less.

Page 22
Image 22
Honeywell STR12D warranty Table II Seals