Honeywell TS815 Specifications, Temperature remote, Humidity Indoor, Radio Frequency 433 MHz

Models: TE852W TE852ELW TS815

1 23
Download 23 pages 11.48 Kb
Page 21
Image 21
Temperature (remote)

Milan, Italy

MIL

1

SE

Montevideo,

MVD

-3

SM

Moscow, Russia

MOW

3

SK

Munich, Germany

MUC

1

SE

Nairobi, Kenya

NBO

3

NO

Nanjing

NKG

8

NO

Naples, Italy

NAP

1

SE

New Delhi, India

DEL

5.5

NO

Odessa, Ukraine

ODS

2

SE

Osaka, Japan

KIX

9

NO

Singapore,

SIN

8

NO

Sofia, Bulgaria

SOF

2

SE

Stockholm Arlanda,

ARN

1

SE

Sydney, Australia

SYD

10

SA

Tokyo, Japan

TKO

9

NO

Tripoli, Libya

TRP

2

NO

Vienna, Austria

VIE

1

SE

Warsaw, Poland

WAW

1

SE

Zürich, Switzerland

ZRH

1

SE

 

 

 

 

Operating Range: 23°F to 122°F (-5°C to 50°C)

Resolution: 0.2°F (0.1°C)

Accuracy: 2°F (1°C)

Sampling Interval: 10 seconds

Temperature (remote)

Range: -40°F to 176°F (-40°C to 80°C)

Resolution: 0.2°F (0.1°C)

Accuracy: 2°F (1°C)

Transmitting Interval: around 47 seconds

Humidity (Indoor)

Operating Range: 30% to 80%

DST (Daylight Savings Time) definitions:

SA = Australian DST.

SB = South Brazilian DST. Changes annually.

SC = Chile DST

SE = Standard European DST.

SG = Egypt DST

SH = Havana, Cuba DST

SI = Iraq and Syria DST

SK = Irkutsk & Moscow DST

SM = Montevideo, Uruguay DST

SN = Namibia DST

SP = Paraguay DST

SQ = Iran DST maybe changed annually.

ST = Tasmania DST

SU = Standard American DST.

SZ = New Zealand DST

NO DST = no = Places that do not observe DST;

ON = Always add 1 hour to the local standard time

SPECIFICATIONS

Radio Frequency: 433 MHz

RF Reception range: 100-328 feet (30 -100 m)

Barometric Pressure

Measuring Range: 14.75 inHg to 32.44 inHg (500 Hpa to 1100Hpa); (374.5 mmHg to 823.8 mmHg)

Resolution:

0.003 inHg (0.1 Hpa, 0.08 mmHg)

Accuracy:

0.015 inHg (0.5 Hpa; 0.38 mmHg)

Sampling interval: 20 minutes

Altitude Compensation Range: -657 ft to 16404 ft (-200m to +5000 m)

Temperature (Indoor)

41

Resolution: 1%

Accuracy: 5%

Sampling Interval: 10 seconds

Humidity (Outdoor)

Operating Range: 30% to 80%

Resolution: 1%

Accuracy: 5%

Sampling Interval: 10 seconds

Transmitting Interval: around 47 seconds

Sunrise and Sunset

Accuracy: 1min (latitude within 50°)

Wind Speed

Range: 0 to 100 mph (160 Km/h, 86.897 Knots)

Resolution: 0.1mph (0.16 Km/h)

Accuracy: (2mph + 5%)

Starting Threshold: 3mph (4.8 Km/h)

Wind/Gust Speed Display Update Interval: 33 seconds

Wind/Gust Sampling Interval: 11 seconds

Power

Main unit: 2 x UM-3 or AA 1.5V battery

Remote Thermo Hygrometer: 2 x UM-3 or AA 1.5V battery

Remote Wind Meter: 2 x UM-3 or AA 1.5V battery

Battery life (alkaline)

Main unit: 2 month

Thermo-Hygrometer: over 12 months

Remote Wind Meter: over 12 months

Weight (without batteries)

Main unit: 8.15oz (231g)

Remote Thermo-Hygrometer: 2.29oz (65g)

Remote Wind Meter: 11.12oz (315g)

Dimensions

4142