INSTALLATION: «GAS CONNECTION»

INSTALLATION: «GAS CONNECTION»

 

GAZ/GAS

G20

G25

G 30

G 31

 

 

 

 

 

 

 

 

20 mbar

25 mbar

29 mbar

37 mbar

 

 

 

 

 

 

CAT. II2H3+

GB-IT-PT-ES

¤

 

X

X

 

 

 

 

 

 

CAT. II2E+3+

FR

¤

¤

X

X

 

 

 

 

 

 

¤ = Factory setting: Natural gas = G20-20 mbar / G25-25 mbar

X = Gas setting possible according to installation Butane gas G30-29 mbar or Propane gas G 31-37 mbar

CHANGING THE GAS TYPE : the calorific power output and gas pressure will vary according to the gas supply. Burner setting must be carried out once the gas and electrical installation is complete.

When changing gas type, you must follow the procedure below :

. fit the correct jets,

. adjust the minimum flame on the taps.

CHANGING THE JETS

To gain access to the jets, remove the pan supports, and remove the burner cap and body,

Take a spanner and unscrew the jet.

JET

According to the table below, fit the correct jet for the

type of gas to be used, Secure the jet tightly,

Replace the burner body, cap and the pan support.

Each jet is designated by size.

 

 

 

 

 

 

 

HOB BURNERS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

auxiliary

semi-rapid

rapid

ultra-

4 Rings

 

 

 

 

 

rapid

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas

mbar

Jet

kW

Jet

kW

Jet

kW

Jet

Jet

kW

 

 

 

 

 

 

 

 

 

 

 

 

 

*

 

G 20

20

76

1,00

101

1,75

118

2,50

144

141

3,50

 

 

 

 

 

 

 

 

 

 

 

 

 

*

 

G 25

25

76

0,90

101

1,60

118

2,30

144

141

3,20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G 30

29

50

1,00

66

1,75

80

2,50

94

96

3,50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G 31

37

50

1,00

66

1,75

80

2,50

94

96

3,50

 

 

 

 

 

 

 

 

 

 

 

 

 

*

 

Factory setting: G 20-20 mbar - G 25-25 mbar

 

 

 

 

 