INSTALLATION: «GAS CONNECTION»
| GAZ/GAS | G20 | G25 | G 30 | G 31 |
|
|
|
|
|
|
|
| 20 mbar | 25 mbar | 29 mbar | 37 mbar |
|
|
|
|
|
|
CAT. II2H3+ | ¤ |
| X | X | |
|
|
|
|
|
|
CAT. II2E+3+ | FR | ¤ | ¤ | X | X |
|
|
|
|
|
|
¤ = Factory setting: Natural gas =
X = Gas setting possible according to installation Butane gas
CHANGING THE GAS TYPE : the calorific power output and gas pressure will vary according to the gas supply. Burner setting must be carried out once the gas and electrical installation is complete.
When changing gas type, you must follow the procedure below :
. fit the correct jets,
. adjust the minimum flame on the taps.
CHANGING THE JETS
To gain access to the jets, remove the pan supports, and remove the burner cap and body,
Take a spanner and unscrew the jet.
JET
According to the table below, fit the correct jet for the
type of gas to be used, Secure the jet tightly,
Replace the burner body, cap and the pan support.
Each jet is designated by size.
|
|
|
|
|
|
| HOB BURNERS |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| auxiliary | rapid | ultra- | 4 Rings |
| ||||
|
|
|
| rapid |
| |||||||
|
|
|
|
|
|
|
|
|
|
|
| |
| Gas | mbar | Jet | kW | Jet | kW | Jet | kW | Jet | Jet | kW | |
|
|
|
|
|
|
|
|
|
|
|
|
|
* |
| G 20 | 20 | 76 | 1,00 | 101 | 1,75 | 118 | 2,50 | 144 | 141 | 3,50 |
|
|
|
|
|
|
|
|
|
|
|
|
|
* |
| G 25 | 25 | 76 | 0,90 | 101 | 1,60 | 118 | 2,30 | 144 | 141 | 3,20 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| G 30 | 29 | 50 | 1,00 | 66 | 1,75 | 80 | 2,50 | 94 | 96 | 3,50 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| G 31 | 37 | 50 | 1,00 | 66 | 1,75 | 80 | 2,50 | 94 | 96 | 3,50 |
|
|
|
|
|
|
|
|
|
|
|
|
|
* |
| Factory setting: G |
|
|
|
|
|