Hoshizaki DCM-500BWH-OS, DCM-500BAH-OS Startup, Hour Drain Cycle Shutdown & Restart

Models: DCM-500BWH DCM-500BAH DCM-500BWH-OS DCM-500BAH-OS

1 69
Download 69 pages 4.5 Kb
Page 13
Image 13
1. Startup

DCM-500BAH(-OS), DCM-500BWH(-OS) Sequence Flow Chart and Component Operation

4. 12 Hour Drain Cycle

DV opens for 20 minutes every 12 hours

See "3. 12 Hour Drain Cycle" below.

1. Startup

Power switch "ON" Control switch in "ICE"

1. Fill Cycle

2.Ice Purge Cycle

60 seconds

3. Freeze Cycle

Refill 2.Shutdown & Restart (90 seconds)

Low Water Safety

If refill > 90 sec. FT, 150 second shutdown sequence begins

150 sec. Shutdown Sequence

90 seconds

 

60 seconds

 

 

 

13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WV on

 

 

 

LF/S closed

Comp on

UF/S open

LF/S closed

UF/S open

Comp off

GM off

 

 

 

 

UF/S open

 

 

 

 

UF/S closed (WV off)

FMS on

LF/S open (WV on)

UF/S closed (WV off)

FT exceeded

FMS off

GMPR off

 

 

 

 

 

 

 

WCR on

WCR continues

WCR off

WCR on

Comp continues

WV continues

WV continues until

 

 

 

 

 

 

 

 

 

 

 

 

WV off

GM continues

FT started (90 sec.)

FT off (90 sec.)

FMS continues

GM continues

UF/S closes

 

 

 

 

 

 

GM on

GMPR continues WV on

WV off

GM continues

GMPR continues

 

 

 

 

 

 

 

 

 

GMPR on

 

 

Comp continues

Comp continues

GMPR continues

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FMS continues

FMS continues

WV continues

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GM continues

GM continues

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GMPR continues

GMPR continues

 

 

 

 

 

 

 

 

2.Shutdown & Restart

3.12 Hour Drain Cycle Shutdown & Restart

 

 

1. Bin Full

 

 

2. Ice Purge Cycle

 

 

 

150

 

 

 

 

 

 

 

 

seconds

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90 seconds

 

60 seconds

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Drain Cycle initiates

 

 

 

2. Ice Purge Cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3. Icemaker is Off

 

4. Ice Level Lowered

 

 

 

 

 

See "1. Fill Cycle" above

 

 

 

 

 

3. Drain Cycle

4. 12 hour DC - Restart

DV on for 20 minutes

See "1. Fill Cycle" above

Legend:

BC - bin control Comp - compressor DC - drain cycle DT - drain timer DV - drain valve

FMS - self-contained fan motor

BC open or DC starts

Comp off

GM off

BC closed

Comp continues

FMS off

GMPR off

or

FMS continues

GM continues

DV on (DC only)

20 Min. DT off (DC only)

GM continues

GMPR continues

 

DV off (DC only)

GMPR continues

 

 

12 hour DT reset (DC only)

Components Energized when the Control Switch is in the "DRAIN" Position

The "DRAIN" position on the control switch is used when cleaning and sanitizing the unit. This allows cleaner and sanitizer to drain from the reservoir and evaporator assembly. When switching to the "DRAIN" position during the freeze cycle, the drain valve does not energize until the 150 second shutdown sequence terminates (2. Shutdown & Restart).

Note: To bypass the 150 second shutdown sequence, move the power switch to the "OFF" position, place the control switch in the "DRAIN" position, then move the power switch back to the "ON" position.

FT - fill timer (low water safety) GM - gear motor

GMPR - gear motor protect relay LF/S - lower float switch UF/S - upper float switch WCR - water control relay

WV - inlet water valve