Hoshizaki DCM-500BAH-OS, DCM-500BWH-OS service manual C. Diagnostic Charts, No Ice Production

Models: DCM-500BWH DCM-500BAH DCM-500BWH-OS DCM-500BAH-OS

1 69
Download 69 pages 4.5 Kb
Page 38
Image 38

C. Diagnostic Charts

1. No Ice Production

Problem

Possible Cause

 

 

Remedy

 

 

 

 

 

 

[1] The icemaker will not

a) Power Supply

1.

Off, blown fuse, or

1.

Turn on, replace, or reset.

start. (Fill Cycle)

 

 

 

tripped breaker.

 

 

 

 

 

 

 

 

 

 

2. Loose connection.

2. Tighten.

 

 

 

3. Bad contacts.

3. Check for continuity and

 

 

 

 

 

 

replace.

 

 

 

 

 

 

 

 

4. Not within

4. Refer to nameplate and

 

 

 

 

specifications.

 

correct.

 

 

 

 

 

 

 

b) Water Supply

1.

Water supply off or

1.

Check and get

 

 

 

 

pressure too low.

 

recommended pressure.

 

 

 

 

 

 

 

c) Power Switch

1.

"OFF" position.

1.

Move to "ON" position.

 

 

(Control Box)

 

 

 

 

 

 

2. Bad contacts.

2. Check for continuity and

 

 

 

 

 

 

 

 

 

replace.

 

d) Door Switch

1.

Door switch not

1.

Engage door switch.

 

 

 

 

engaged.

 

 

 

 

 

 

 

 

 

 

2. Bad contacts.

2. Check for continuity and

 

 

 

 

 

 

replace.

 

 

 

 

 

 

 

e) Power Protect Relay

1.

Voltage not within

1.

Refer to nameplate and

 

 

 

 

specifications.

 

correct.

 

 

 

 

 

 

 

 

2. Bad contacts.

2. Check for continuity and

 

 

 

 

 

 

replace.

 

f)

Transformer

1.

Coil winding open.

1.

Replace.

 

 

 

 

 

 

 

g) Fuses (2)

1.

Blown.

1.

Check for short circuit and

 

 

 

 

 

 

replace.

 

 

 

 

 

 

 

h) Control Switch

1.

"OFF" or "DRAIN"

1.

Move to "ICE" position.

 

 

 

 

position.

 

 

 

 

 

 

 

 

 

 

2. Bad contacts.

2. Check for continuity and

 

 

 

 

 

 

replace.

 

i)

Water Control Relay

1.

Bad contacts.

1.

Check for continuity and

 

 

 

 

 

 

replace.

 

 

 

 

 

 

 

 

2. Coil winding open.

2. Replace.

 

 

 

 

 

 

 

 

j)

Inlet Water Valve

1.

Mesh filter or orifice

1.

Clean.

 

 

 

 

clogged.

 

 

 

 

 

 

 

 

 

 

2. Coil winding open.

2. Replace.

 

 

 

3. Wiring to inlet water

3. Check for loose or open

 

 

 

 

valve.

 

connection. Repair or

 

 

 

 

 

 

replace.

 

 

 

 

 

 

 

k) Float Switch

1.

Bad contacts.

1.

Check for continuity and

 

 

 

 

 

 

replace.

 

 

 

 

 

 

 

 

2. Float does not move

2. Clean or replace.

 

 

 

 

freely.

 

 

 

 

 

 

 

 

 

 

l)

Bin Control

1.

Open.

1.

Bin full, check for

 

 

 

 

 

 

continuity on proximity

 

 

 

 

 

 

switch.

 

 

 

2. Actuator sticking.

2. Adjust or replace.

 

 

 

 

 

 

 

 

3. Proximity switch open.

3. Replace.

 

 

 

 

 

 

 

38

Page 38
Image 38