Hoshizaki DCM-500BAH-OS service manual DCM-500BWH-OS, Approximate

Models: DCM-500BWH DCM-500BAH DCM-500BWH-OS DCM-500BAH-OS

1 69
Download 69 pages 4.5 Kb
Page 35
Image 35
Manual background

2. DCM-500BWH(-OS)

APPROXIMATE

Ambient

 

 

Water Temp. (°F)

 

ICE PRODUCTION

Temp. (°F)

 

50

 

70

 

90

PER 24 HR.

70

* 567

257

549

249

539

244

 

80

529

240

519

235

509

231

 

90

500

227

* 495

224

481

218

lbs./day ( l/day)

100

472

214

464

210

* 428

194

APPROXIMATE ELECTRIC

70

* 976

--

967

--

991

--

CONSUMPTION

80

976

--

967

--

991

--

 

90

976

--

* 967

--

991

--

watts

100

976

--

967

--

* 991

--

APPROXIMATE WATER

70

* 111

0.51

130

0.59

194

0.88

CONSUMPTION PER 24 HR.

80

111

0.50

130

0.59

198

0.90

(TOTAL)

90

110

0.50

* 130

0.59

203

0.92

gal. / day (kl/day)

100

110

0.50

132

0.60

* 214

0.97

EVAPORATOR OUTLET TEMP.

70

* 19

-7

19

-7

19

-7

°F (°C)

80

19

-7

19

-7

19

-7

 

90

19

-7

* 19

-7

19

-7

 

100

19

-7

19

-7

* 19

-7

HEAD PRESSURE

70

* 266

18.7

267

18.8

270

19.0

 

80

266

18.7

267

18.8

270

19.0

PSIG (kg/cm2G)

90

266

18.7

* 267

18.8

270

19.0

100

266

18.7

267

18.8

* 270

19.0

SUCTION PRESSURE

70

* 44

3.1

44

3.1

47

3.3

PSIG (kg/cm2G)

80

44

3.1

44

3.1

47

3.3

 

90

44

3.1

* 44

3.1

47

3.3

 

100

44

3.1

44

3.1

* 47

3.3

WATER FLOW FOR CONDENSER

21 gal/h (AT 90°F /WT 70°F)

PRESSURE DROP OF COOLING WATER LINE

Less than 7 PSIG

HEAT OF REJECTION FROM CONDENSER

5438 BTU/h (AT 90°F /WT 70°F)

HEAT OF REJECTION FROM COMPRESSOR

1104 BTU/h (AT 90°F /WT 70°F)

Note:

1.The data without *marks should be used for reference only.

2.We reserve the right to make changes in specifications and design without prior notice.