2.
APPROXIMATE | Ambient |
|
| Water Temp. (°F) |
| ||
ICE PRODUCTION | Temp. (°F) |
| 50 |
| 70 |
| 90 |
PER 24 HR. | 70 | * 567 | 257 | 549 | 249 | 539 | 244 |
| 80 | 529 | 240 | 519 | 235 | 509 | 231 |
| 90 | 500 | 227 | * 495 | 224 | 481 | 218 |
lbs./day ( l/day) | 100 | 472 | 214 | 464 | 210 | * 428 | 194 |
APPROXIMATE ELECTRIC | 70 | * 976 | 967 | 991 | |||
CONSUMPTION | 80 | 976 | 967 | 991 | |||
| 90 | 976 | * 967 | 991 | |||
watts | 100 | 976 | 967 | * 991 | |||
APPROXIMATE WATER | 70 | * 111 | 0.51 | 130 | 0.59 | 194 | 0.88 |
CONSUMPTION PER 24 HR. | 80 | 111 | 0.50 | 130 | 0.59 | 198 | 0.90 |
(TOTAL) | 90 | 110 | 0.50 | * 130 | 0.59 | 203 | 0.92 |
gal. / day (kl/day) | 100 | 110 | 0.50 | 132 | 0.60 | * 214 | 0.97 |
EVAPORATOR OUTLET TEMP. | 70 | * 19 | 19 | 19 | |||
°F (°C) | 80 | 19 | 19 | 19 | |||
| 90 | 19 | * 19 | 19 | |||
| 100 | 19 | 19 | * 19 | |||
HEAD PRESSURE | 70 | * 266 | 18.7 | 267 | 18.8 | 270 | 19.0 |
| 80 | 266 | 18.7 | 267 | 18.8 | 270 | 19.0 |
PSIG (kg/cm2G) | 90 | 266 | 18.7 | * 267 | 18.8 | 270 | 19.0 |
100 | 266 | 18.7 | 267 | 18.8 | * 270 | 19.0 | |
SUCTION PRESSURE | 70 | * 44 | 3.1 | 44 | 3.1 | 47 | 3.3 |
PSIG (kg/cm2G) | 80 | 44 | 3.1 | 44 | 3.1 | 47 | 3.3 |
| 90 | 44 | 3.1 | * 44 | 3.1 | 47 | 3.3 |
| 100 | 44 | 3.1 | 44 | 3.1 | * 47 | 3.3 |
WATER FLOW FOR CONDENSER | 21 gal/h (AT 90°F /WT 70°F) |
PRESSURE DROP OF COOLING WATER LINE | Less than 7 PSIG |
HEAT OF REJECTION FROM CONDENSER | 5438 BTU/h (AT 90°F /WT 70°F) |
HEAT OF REJECTION FROM COMPRESSOR | 1104 BTU/h (AT 90°F /WT 70°F) |
Note:
1.The data without *marks should be used for reference only.
2.We reserve the right to make changes in specifications and design without prior notice.
35