3. DCM-500BWH
AC SUPPLY VOLTAGE | 115/60/1 |
|
|
|
|
|
|
|
| ||
COMPRESSOR | 120 V |
| 7.9 RLA | 51 LRA |
|
| |||||
GEAR MOTOR |
| 120 V |
| 2.4 FLA | 1/4 HP |
|
| ||||
AGITATING MOTOR | 120 V |
| 0.9 FLA | 55 W |
|
|
| ||||
DISPENSING MOTOR | 120 V |
| 0.9 FLA | 55 W |
|
|
| ||||
OTHERS |
| 120 V |
| 0.2 A |
|
|
|
|
| ||
MAXIMUM FUSE SIZE | 20 A |
|
|
|
|
|
|
| |||
MAX. HACR BREAKER (USA ONLY) | 20 A |
|
|
|
|
|
|
| |||
MAX. CIRC. BREAKER (CANADA ONLY) | 20 A |
|
|
|
|
|
|
| |||
MINIMUM CIRCUIT AMPACITY | 20 A |
|
|
|
|
|
|
| |||
APPROXIMATE ICE PRODUCTION | Ambient |
|
|
| WATER TEMP. (°F) |
|
| ||||
PER 24 HR. |
| Temp. (°F) |
| 50 | 70 | 90 |
| ||||
lbs./day ( kg/day ) | 70 |
|
| * 567 | (257) | 549 | (249) | 539 | (244) |
| |
Reference without * marks | 80 |
|
| 529 (240) | 519 (2335) | 509 (231) |
| ||||
|
| 90 |
|
| 500 | (227) | * 495 | (224) | 481 | (218) |
|
SHAPE OF ICE |
| 100 |
|
| 472 | (214) | 464 | (210) | * 428 | (194) |
|
| Cubelet | (Compressed Flake Ice) |
|
|
| ||||||
ICE QUALITY |
| Approx. 90% Ice (90/70° F, Conductivity 200 µs/cm) | |||||||||
APPROXIMATE STORAGE CAPACITY | 40 lbs. |
|
|
|
|
|
|
|
|
| |
ELECTRIC & WATER CONSUMPTION | 90/70°F | 70/50°F |
|
|
|
|
| ||||
ELECTRIC | W (kWH/100 lbs.) | 967 (4.7) |
| 991 (4.1) |
|
|
|
|
| ||
POTABLE WATER | 60 (12) |
| 68 (12) |
|
|
|
|
| |||
WATER - COOLED CONDENSER | 352 (71.2) |
| 251 (44.3) |
|
|
|
|
| |||
gal./24HR | (gal./100 lbs.) |
|
|
|
|
|
|
|
|
|
|
EXTERIOR DIMENSIONS (WxDxH) | 26" x |
|
| ||||||||
EXTERIOR FINISH | Stainless Steel, Galvanized Steel (Rear) |
|
| ||||||||
WEIGHT |
| Net 245 lbs. (111 kg), Shipping 269 lbs. (122 kg) | |||||||||
CONNECTIONS - ELECTRIC | Permanent Connection |
|
|
|
|
| |||||
- WATER SUPPLY | Inlet | 1/2" FPT | Condenser Inlet 1/2"FPT | ||||||||
- DRAIN | Outlet | 3/4" FPT x2 Condenser Outlet 3/8" FPT | |||||||||
ICE MAKING SYSTEM | Auger type |
|
|
|
|
|
|
| |||
HARVESTING SYSTEM | Direct Driven Auger ( 1/4 HP Gear Motor ) |
|
| ||||||||
ICE MAKING WATER CONTROL | Float Switch |
|
|
|
|
|
| ||||
COOLING WATER CONTROL | Automatic Water Regulator |
|
|
|
| ||||||
BIN CONTROL SYSTEM | Mechanical Bin Control ( Proximity Sw. ) |
|
| ||||||||
COMPRESSOR | Hermetic, Model |
|
|
| |||||||
CONDENSER |
| Water Cooled, Double Tube Type |
|
|
| ||||||
EVAPORATOR |
| Copper Tube on Cylinder |
|
|
|
| |||||
REFRIGERANT CONTROL | Thermostatic Expansion Valve |
|
|
|
| ||||||
REFRIGERANT CHARGE | R404A |
|
| 14.1 oz. (400g) |
|
|
|
| |||
DESIGN PRESSURE | High 460 PSIG |
| Low 290 PSIG |
|
| ||||||
P.C. BOARD CIRCUIT PROTECTION | High Voltage |
|
|
|
| ||||||
COMPRESSOR PROTECTION |
|
|
|
| |||||||
GEAR MOTOR PROTECTION |
|
|
|
| |||||||
|
| Fuse |
|
|
|
|
|
|
|
|
|
REFRIGERANT CIRCUIT PROTECTION |
|
| |||||||||
LOW WATER PROTECTION | Float Switch and Timer |
|
|
|
|
| |||||
ACCESSORIES - SUPPLIED | Spare Fuse |
|
|
|
|
|
|
| |||
- REQUIRED | Legs |
|
|
|
|
|
|
|
|
| |
OPERATING CONDITIONS | VOLTAGE RANGE |
|
| ||||||||
|
| AMBIENT TEMP. |
|
|
| ||||||
|
| WATER SUPPLY TEMP. |
| ||||||||
|
| WATER SUPPLY PRESSURE |
|
Note: We reserve the right to make changes in specifications and design without prior notice.