4. TIMING CHART
1. CIRCUIT PROTECT | ON | |
RELAY | OFF | |
| UPPER | |
2. WATER LEVEL | LOWER | |
| BOTTOM | |
UPPER | ON | |
OFF | ||
3. FLOAT | ||
| ||
SWITCH | ON | |
LOWER | ||
OFF | ||
| ||
4. WATER CONTROL | ON | |
RELAY | OFF | |
5. CONTROL WATER | ON | |
VALVE | OFF | |
6. FLUSH TIMER | 1 - 2 | |
2 - 3 | ||
| ||
7. FLUSH SWITCH | FLUSH | |
ICE | ||
| ||
8. FLUSH WATER | ON | |
VALVE | OFF | |
9. BIN CONTROL | ON | |
| ||
| OFF | |
10. GEAR MOTOR | ON | |
RELAY | OFF | |
11. GEAR MOTOR | ON | |
OFF | ||
| ||
12. FAN MOTOR | ON | |
OFF | ||
| ||
13. COMPRESSOR | ON | |
OFF | ||
| ||
14. PRESSURE | ON | |
SWITCH | OFF | |
15. HEATER | ON | |
OFF | ||
|
Miswiring. Circuit Protect Relay operates.)
Proper wiring. The unit starts. | BIN CONTROL | |
| ||
| OFF | ON |
1 sec | 6 sec | 1 sec |
60 sec | 60 sec |
38