Hoshizaki F-1000MAF/-C, F-1000MLF/-C Low Ice Production, Problem, Possible Cause, Remedy

Models: F-1000MWF/-C F-1000MRF/-C F-1000MLF/-C F-1000MAF/-C

1 74
Download 74 pages 9.65 Kb
Page 52
Image 52

2. LOW ICE PRODUCTION

PROBLEM

 

POSSIBLE CAUSE

 

REMEDY

[1] Low ice production

a)

Refrigerant Line

1.

Gas leaks.

1.

See "1. [5] a)

 

 

 

 

 

 

Refrigerant Line."

 

 

 

2.

Refrigerant line

2.

Replace the clogged

 

 

 

 

clogged.

 

component.

 

 

 

3.

Overcharged.

3.

Recharge.

 

b)

High-side Pressure

1.

Dirty Air Filter or

1.

Clean.

 

 

Too High

 

Condenser.

 

 

 

 

 

2.

Ambient or

2.

Get cooler.

 

 

 

 

condenser water

 

 

 

 

 

 

temperature too

 

 

 

 

 

 

warm.

 

 

 

 

 

3.

Condenser water

3.

Check and get

 

 

 

 

pressure too low or

 

recommended

 

 

 

 

off. [Water-cooled

 

pressure.

 

 

 

 

model only]

 

 

 

 

 

4.

Fan rotating too

4.

See "3 [1] a) Fan

 

 

 

 

slow.

 

Motor."

 

 

 

5.

Water Regulating

5.

Clean.

 

 

 

 

Valve clogged.

 

 

 

 

 

 

[Water-cooled model

 

 

 

 

 

 

only]

 

 

 

 

 

6.

Condensing unit out

6.

Check condensing

 

 

 

 

of order.

 

unit.

 

c)

Expansion Valve

1.

Low-side pressure

1.

Replace.

 

 

(not adjustable)

 

too low.

 

 

 

 

 

2.

Low-side pressure

2.

See if Expansion

 

 

 

 

too high.

 

Valve Bulb is mounted

 

 

 

 

 

 

properly, and replace

 

 

 

 

 

 

the valve if necessary.

52

Page 52
Image 52
Hoshizaki F-1000MAF/-C, F-1000MLF/-C, F-1000MRF/-C, F-1000MWF/-C Low Ice Production, Problem, Possible Cause, Remedy