F-1000MRF

APPROXIMATE

Ambient

 

 

Water Temp. (F)

 

ICE PRODUCTION

Temp. (F)

 

50

 

70

 

90

PER 24 HR.

70

930

(422)

895

(407)

865

(393)

 

80

835

(379)

805

(366)

780

(353)

 

90

750

(341)

745

(338)

700

(317)

lbs./day (kg/day)

100

675

(306)

650

(296)

605

(274)

APPROXIMATE ELECTRIC

70

1285

--

1285

--

1290

--

CONSUMPTION

80

1290

--

1290

--

1290

--

 

90

1295

--

1295

--

1305

--

watts

100

1310

--

1320

--

1325

--

APPROXIMATE WATER

70

112

(422)

108

(407)

104

(393)

CONSUMPTION PER 24 HR.

80

100

(379)

97

(366)

93

(353)

gal./day (l/day)

90

90

(341)

89

(338)

84

(317)

100

81

(306)

78

(296)

73

(274)

EVAPORATOR OUTLET TEMP.

70

23

(-5)

24

(-4)

25

(-4)

 

80

25

(-4)

26

(-3)

26

(-3)

 

90

26

(-3)

27

(-3)

28

(-2)

°F (°C)

100

28

(-2)

28

(-2)

28

(-2)

HEAD PRESSURE

70

221

(15.5)

221

(15.5)

221

(15.5)

 

80

239

(16.8)

239

(16.8)

239

(16.8)

PSIG (kg/cm²G)

90

256

(18.0)

256

(18.0)

256

(18.0)

100

295

(20.7)

295

(20.7)

295

(20.7)

SUCTION PRESSURE

70

33

(2.3)

33

(2.3)

33

(2.3)

 

80

35

(2.4)

35

(2.4)

35

(2.4)

PSIG ( kg/cm²G )

90

36

(2.5)

36

(2.5)

36

(2.5)

100

39

(2.7)

39

(2.7)

39

(2.7)

CONDENSER VOLUME

74.5 cu in

HEAT OF REJECTION FROM CONDENSER

7660 BTU/h (AT 90°F /WT 70°F)

HEAT OF REJECTION FROM COMPRESSOR

1380 BTU/h (AT 90°F /WT 70°F)

Note: The data without *marks should be used for reference.

We reserve the right to make changes in specifications and design without prior notice.