BEARING-LOWER AND MECHANICAL SEAL

13)Recover the refrigerant and store it in an approved container, if required by an applicable law.

IMPORTANT

Always install a new Drier every time the sealed refrigeration system is opened. Do not replace the Drier until after all other repairs or replacement have been made.

14)Remove the Bulb of the Expansion Valve.

15)Disconnect the brazing-connections of the Expansion Valve and the Copper Tube - Low Side from the Evaporator, using brazing equipment.

16)Remove the two Truss Head Machine Screws and the Strap securing the Evaporator.

17)Disconnect the three Hoses from the Evaporator.

18)Remove the four Socket Head Cap Screws securing the Evaporator with the Bearing- Lower.

19)Lift off the Evaporator.

BEARING-LOWER AND MECHANICAL SEAL

20)The Mechanical Seal consists of two parts. One moves along with the Auger, and the other is fixed on the Bearing-Lower. If the contact surfaces of these two parts are worn or scratched, the Mechanical Seal may cause water leaks and should be replaced.

21)Remove the O-ring on the Bearing-Lower.

22)Remove the four Bolts and the Bearing-Lower from the Gear Motor. Replace the Bearing inside the Bearing-Lower, if it exceeds the wear tolerance of 0.02" or is scratched.

Note: Replacing the Bearing requires a bearing press adaptor. If it is not available, replace the whole Bearing-Lower.

GEAR MOTOR

23)Remove the Coupling-Spline on the Gear Motor Shaft.

24)Remove the Barrier on the top of the Gear Motor.