Hoshizaki F-1000MWF/-C, F-1000MAF/-C, F-1000MLF/-C, F-1000MRF/-C service manual F-1000MRF-C

Models: F-1000MWF/-C F-1000MRF/-C F-1000MLF/-C F-1000MAF/-C

1 74
Download 74 pages 9.65 Kb
Page 47
Image 47
Manual background

F-1000MRF-C

APPROXIMATE

Ambient

 

 

Water Temp. (F)

 

ICE PRODUCTION

Temp. (F)

 

50

 

70

 

90

PER 24 HR.

70

840

(381)

810

(368)

790

(358)

 

80

765

(347)

745

(337)

720

(327)

 

90

700

(317)

695

(315)

660

(299)

lbs./day (kg/day)

100

640

(290)

620

(282)

575

(261)

APPROXIMATE ELECTRIC

70

1300

--

1300

--

1305

--

CONSUMPTION

80

1305

--

1505

--

1305

--

 

90

1310

--

1310

--

1320

--

watts

100

1325

--

1335

--

1340

--

APPROXIMATE WATER

70

101

(381)

98

(368)

95

(358)

CONSUMPTION PER 24 HR.

80

92

(347)

89

(337)

87

(327)

gal./day (l/day)

90

84

(317)

83

(315)

79

(299)

100

77

(290)

75

(282)

69

(261)

EVAPORATOR OUTLET TEMP.

70

23

(-5)

24

(-4)

25

(-4)

 

80

25

(-4)

26

(-3)

26

(-3)

 

90

26

(-3)

25

(-4)

28

(-2)

°F (°C)

100

28

(-2)

28

(-2)

28

(-2)

HEAD PRESSURE

70

220

(15.5)

220

(15.5)

220

(15.5)

 

80

238

(16.7)

238

(16.7)

238

(16.7)

PSIG (kg/cm²G)

90

256

(18.0)

256

(18.0)

256

(18.0)

100

295

(20.7)

295

(20.7)

295

(20.7)

SUCTION PRESSURE

70

34

(2.4)

34

(2.4)

33

(2.4)

 

80

36

(2.5)

36

(2.5)

36

(2.5)

PSIG ( kg/cm²G )

90

37

(2.6)

37

(2.6)

37

(2.6)

100

40

(2.8)

40

(2.8)

40

(2.8)

CONDENSER VOLUME

74.5 cu in

HEAT OF REJECTION FROM CONDENSER

7840 BTU/h (AT 90°F /WT 70°F)

HEAT OF REJECTION FROM COMPRESSOR

1400 BTU/h (AT 90°F /WT 70°F)

Note: The data without *marks should be used for reference.

We reserve the right to make changes in specifications and design without prior notice.

47

Page 47
Image 47
Hoshizaki F-1000MWF/-C, F-1000MAF/-C, F-1000MLF/-C, F-1000MRF/-C service manual F-1000MRF-C