6)Turn on the power supply and drain out all water from the water line.

7)Turn off the power supply.

8)Remove the Control Water Valve by releasing the Fitting Nut. Do not lose the Packing.

9)Remove the Cover of the Reservoir.

10)Fill the Reservoir with the cleaning solution.

11)Replace the Cover of the Reservoir and the Control Water Valve in their correct position. Note: This unit is designed to start operating when the Reservoir is filled with water.

12)Move the Flush Switch to the “ICE” position.

13)Replace the Top Panel and the Front Panel in their correct position.

14)Allow the icemaker to set for about 10 minutes before the operation. Then, turn on the power supply, and make ice using the solution until the icemaker stops icemaking.

15)Remove the Front Panel.

16)Move the Flush Switch to the “FLUSH” position to drain the cleaning solution.

17)Move the Flush Switch to the “ICE” position.

18)Replace the Front Panel in its correct position.

19)Open the Water Supply Line Shut-off Valve, and supply water to the Reservoir.

20)Turn off the power supply when the Gear Motor starts.

21)Drain out all water from the water line. See 4) through 7).

<STEP 3>

Use 3/4 gal. of the sanitizing solution to sanitize the icemaker.

1)Close the Water Supply Line Shut-off Valve.

2)Remove the Control Water Valve by releasing the Fitting Nut.

3)Remove the Cover of the Reservoir.

4)Fill the Reservoir with the sanitizing solution.