3. Sanitizing Solution

19)When the gear motor starts, remove the front panel and move the flush switch to the "FLUSH" position to drain out the water from the icemaker.

20)After the water has drained, move the power switch to the "OFF" position and unplug

the unit.

Note: If you do not sanitize the icemaker, leave the unit plugged in with the power switch in the "ON" position and go to step 18 in "5. Sanitizing Procedure - Final."

3. Sanitizing Solution

Dilute 2.5 fl. oz. (74 ml or 5 tbs) of a 5.25% sodium hypochlorite solution (chlorine bleach) with 5 gallons (19 l) of warm water.

IMPORTANT

For safety and maximum effectiveness, use the solution immediately after dilution.

4.Sanitizing Procedure - Initial

1)Close the water supply line shut-off valve.

2)Remove the top panel. Remove the bin control assembly from the top insulation and set it aside. Remove the top insulation.

3)Remove the thumbscrews attaching spout (B) to the bin, then remove spout (B).

4)Remove the thumbscrews attaching spout (A) and safety bracket (A) to the evaporator assembly, then remove spout (A) and safety bracket (A). Remove spout packing (A) and the cylinder packing. See Fig. 5.

5)Pour the sanitizing solution over the extruding head until the evaporator assembly and the reservoir are filled and the solution starts to overflow into the drain pan.

6)Lift up slightly on the clip securing the bin control switch to the paddle assembly and slide the switch out. See Fig. 6.

7)Soak the spouts, packings and paddle assembly in

.25 gallons (1 l) of sanitizing solution for 10 minutes then wipe them down.

8)Rinse the parts thoroughly, then replace all parts in their correct positions.

9)Plug the unit back in. Move the flush switch to the "ICE" position and move the power switch to the "ON" position. Replace the panels in their correct positions and allow the unit to make ice using the solution until it stops automatically.

5.Sanitizing Procedure - Final

1)Remove the front panel.

Clip

Bin Control

Switch

Paddle

Fig. 6

Assembly

 

2)Move the flush switch to the "FLUSH" position to drain the remainder of the solution.

3)After the solution has drained, move the power switch to the "OFF" position and unplug the unit.