Hoshizaki KMD-900MRH, KMD-900MAH, KMD-700MAH, KMD-700MWH, KMD-700MRH, KMD-900MWH service manual 701

Models: KMD-900MRH KMD-900MWH KMD-700MRH KMD-700MWH KMD-700MAH KMD-900MAH

1 80
Download 80 pages 59.49 Kb
Page 47
Image 47

[b] KMD-700MWH

APPROXIMATE ICE

AMBIENT TEMP.

 

 

WATER TEMP. (ºF/ºC)

 

 

PRODUCTION PER 24 HR.

(ºF/ºC)

 

50/10

 

 

70/21

 

90/32

 

 

 

 

 

70/21

701

318

 

675

306

 

634

288

 

 

 

 

80/27

681

309

 

640

290

 

597

271

lbs./day

 

kg./day

 

90/32

675

306

 

611

277

 

569

258

 

100/38

665

302

 

601

273

 

530

240

 

 

 

 

 

 

 

 

 

 

APPROXIMATE ELECTRIC

70/21

 

1500

 

 

1506

 

1543

 

CONSUMPTION

80/27

 

1504

 

 

1514

 

1566

 

 

 

 

 

90/32

 

1506

 

 

1520

 

1567

 

watts

 

 

 

100/38

 

1523

 

 

1531

 

1610

 

APPROXIMATE WATER

70/21

676

2.56

 

715

2.71

 

915

3.46

CONSUMPTION PER 24 HR.

80/27

706

2.67

 

767

2.90

 

1048

3.97

 

 

 

 

90/32

715

2.71

 

810

3.07

 

1061

4.02

gal./day

 

m3/day

100/38

836

3.17

 

869

3.29

 

1291

4.89

FREEZING CYCLE TIME

70/21

 

19

 

 

20

 

21

 

 

 

 

 

80/27

 

19

 

 

20

 

22

 

 

 

 

 

90/32

 

20

 

 

21

 

23

 

min.

 

 

 

100/38

 

20

 

 

21

 

24

 

HARVEST CYCLE TIME

70/21

 

2.2

 

 

2.1

 

2.0

 

 

 

 

 

80/27

 

2.2

 

 

2.1

 

2.0

 

 

 

 

 

90/32

 

2.1

 

 

2.0

 

2.0

 

min.

 

 

 

100/38

 

2.1

 

 

2.0

 

2.0

 

HEAD PRESSURE

70/21

275

19.3

 

276

19.4

 

284

20.0

 

 

 

 

80/27

276

19.4

 

277

19.5

 

289

20.3

 

 

 

 

90/32

276

19.4

 

278

19.5

 

288

20.3

PSIG

kg/cm2G

100/38

280

19.7

 

280

19.7

 

298

21.0

SUCTION PRESSURE

70/21

40

2.8

 

42

2.9

 

49

3.4

 

 

 

 

80/27

41

2.9

 

44

3.1

 

53

3.7

 

 

 

 

90/32

42

2.9

 

46

3.2

 

54

3.8

PSIG

kg/cm2G

100/38

45

3.1

 

48

3.4

 

62

4.4

TOTAL HEAT OF REJECTION FROM CONDENSER

12,200 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

TOTAL HEAT OF REJECTION FROM COMPRESSOR

2,020 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

WATER FLOW FOR CONDENSER

46 GAL./HR [AT 100oF (38oC) / WT 90oF (32oC)]

PRESSURE DROP OF COOLING WATER LINE

LESS THAN 10 PSIG

Note: Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold should be used for reference only.

We reserve the right to make changes in specifications and design without prior notice.