The green LEDs 1-4 represent the corresponding relays and energize and sequence

5 seconds from initial startup as follows:

 

Sequence Step

LED

Time LEDs are Lit

 

Min.

Max.

Avg.

 

 

 

 

1 Minute Fill Cycle

4

 

 

60 seconds

 

Harvest Cycle

1, 4, and 2

2 minutes

20 minutes

3 to 5 minutes

 

 

 

 

 

 

 

Freeze Cycle

1

5 minutes

60 minutes

30 to 35 minutes

 

 

 

 

 

 

 

Reverse Pump Out

1, 3, and 2

10 seconds

20 seconds

factory setting

{LED 1 – Comp; LED 2 - HGV/CFM; LED 3 – PM;

LED 4 - WV}

The built in safeties shut down the unit and have alarms as follows:

No. of Beeps

Type of Alarm

Notes

(every 3 sec.)

 

 

1

High Evaporator Temp.

Check for defrost problem (stuck HGV or relay),

 

(temperature > 127°F)

hot water entering unit, stuck headmaster, or

 

 

shorted thermistor.

 

 

 

2

Defrost Backup Timer

Orange LED marked 20 MIN lights up.

 

(defrost > 20 min.)

Check for open thermistor, HGV not opening, TXV

 

 

leaking by, low charge, or inefficient compressor.

 

 

 

3

Freeze Backup Timer

Yellow LED marked 60 MIN lights up.

 

(freeze > 60 min.)

Check for F/S stuck closed (up), WV leaking by,

 

 

HGV leaking by, TXV not feeding properly, low

 

 

charge, or inefficient compressor.

 

 

 

4

Short Circuit

Check connections and replace wire harness if

 

(between the K4 connection

necessary.

 

on the control board and the

 

 

bin control relay)

 

 

 

 

5

Open Circuit

Check connections and replace wire harness if

 

(between the K4 connection

necessary.

 

on the control board and the

 

 

bin control relay)

 

 

 

 

To manually reset the above safeties, press the white alarm reset button with the power supply on.

6

Low Voltage

 

 

(92Vac or less)

 

7

High Voltage

Red LED will turn off if voltage protection

 

(control voltage

operates.

 

> 147Vac ±5%)

The voltage safety automatically resets when

 

 

voltage is corrected.

The Output Test switch “S3” provides a relay sequence test. With power OFF, place S3 ON and switch power to ICE. The correct lighting sequence should be none, 2, 3, 4, 1, & 4, normal sequence every 5 seconds. (The LEDs are not in numerical order on the board. See the diagram on the next page for the location and numbering of LEDs). S3 should remain in the “OFF” position for normal operation.

21

Page 21
Image 21
Hoshizaki KMD-700MRH, KMD-900MAH, KMD-700MAH, KMD-700MWH, KMD-900MWH, KMD-900MRH service manual Led

KMD-900MRH, KMD-900MWH, KMD-700MRH, KMD-700MWH, KMD-700MAH specifications

The Hoshizaki KMD series offers a range of high-performance ice machines designed to meet the needs of various commercial applications, including restaurants, bars, and healthcare facilities. Models such as the KMD-700MAH, KMD-700MRH, KMD-900MRH, KMD-900MWH, and KMD-900MAH are equipped with innovative technologies and features that ensure efficient ice production and reliable operation.

The KMD-700MAH model is known for its adaptability and efficiency, producing flake ice that is ideal for use in various applications like food preservation, cooling drinks, and more. With a production capacity of up to 700 pounds of ice per day, this model is perfect for medium-sized establishments. Its advanced design incorporates a unique evaporator that enhances ice production while minimizing energy consumption.

Similarly, the KMD-700MRH offers versatility with a similar production capacity, focusing on reliability and performance. This model uses a high-efficiency compressor and a self-contained refrigeration system, ensuring consistent ice production across different ambient conditions. The KMD-700MRH is especially suitable for locations that require frequent and reliable ice replenishment.

The KMD-900 series takes performance a step further, with the KMD-900MRH and KMD-900MAH providing a higher production capacity of up to 900 pounds per day. These machines leverage Hoshizaki’s patented air-cooled technology, which enhances efficiency and reduces operating costs. The robust construction and advanced features make them ideal for high-demand environments.

The KMD-900MWH variant offers an innovative water-cooled option, suitable for businesses in areas with high ambient temperatures or those where air-cooled machines might struggle. By utilizing a water cooling system, it ensures stable performance even in challenging conditions, making it a dependable choice for busy kitchens.

All models in the KMD series feature an easy-to-use digital control panel, which allows for effortless monitoring and adjustments to operations. This technology not only simplifies management but also enables users to receive real-time alerts regarding machine status and maintenance needs, ultimately minimizing downtime.

In summary, the Hoshizaki KMD-700MAH, KMD-700MRH, KMD-900MRH, KMD-900MWH, and KMD-900MAH models are equipped with advanced ice-making technologies designed to deliver high production rates, efficient energy consumption, and reliable performance. Whether it's for a restaurant, bar, or healthcare application, these machines bring together reliability and versatility, making them indispensable tools for any commercial kitchen environment.