Hoshizaki KMD-700MRH, KMD-900MAH, KMD-700MAH, KMD-700MWH, KMD-900MWH, KMD-900MRH service manual Led

Models: KMD-900MRH KMD-900MWH KMD-700MRH KMD-700MWH KMD-700MAH KMD-900MAH

1 80
Download 80 pages 59.49 Kb
Page 21
Image 21

The green LEDs 1-4 represent the corresponding relays and energize and sequence

5 seconds from initial startup as follows:

 

Sequence Step

LED

Time LEDs are Lit

 

Min.

Max.

Avg.

 

 

 

 

1 Minute Fill Cycle

4

 

 

60 seconds

 

Harvest Cycle

1, 4, and 2

2 minutes

20 minutes

3 to 5 minutes

 

 

 

 

 

 

 

Freeze Cycle

1

5 minutes

60 minutes

30 to 35 minutes

 

 

 

 

 

 

 

Reverse Pump Out

1, 3, and 2

10 seconds

20 seconds

factory setting

{LED 1 – Comp; LED 2 - HGV/CFM; LED 3 – PM;

LED 4 - WV}

The built in safeties shut down the unit and have alarms as follows:

No. of Beeps

Type of Alarm

Notes

(every 3 sec.)

 

 

1

High Evaporator Temp.

Check for defrost problem (stuck HGV or relay),

 

(temperature > 127°F)

hot water entering unit, stuck headmaster, or

 

 

shorted thermistor.

 

 

 

2

Defrost Backup Timer

Orange LED marked 20 MIN lights up.

 

(defrost > 20 min.)

Check for open thermistor, HGV not opening, TXV

 

 

leaking by, low charge, or inefficient compressor.

 

 

 

3

Freeze Backup Timer

Yellow LED marked 60 MIN lights up.

 

(freeze > 60 min.)

Check for F/S stuck closed (up), WV leaking by,

 

 

HGV leaking by, TXV not feeding properly, low

 

 

charge, or inefficient compressor.

 

 

 

4

Short Circuit

Check connections and replace wire harness if

 

(between the K4 connection

necessary.

 

on the control board and the

 

 

bin control relay)

 

 

 

 

5

Open Circuit

Check connections and replace wire harness if

 

(between the K4 connection

necessary.

 

on the control board and the

 

 

bin control relay)

 

 

 

 

To manually reset the above safeties, press the white alarm reset button with the power supply on.

6

Low Voltage

 

 

(92Vac or less)

 

7

High Voltage

Red LED will turn off if voltage protection

 

(control voltage

operates.

 

> 147Vac ±5%)

The voltage safety automatically resets when

 

 

voltage is corrected.

The Output Test switch “S3” provides a relay sequence test. With power OFF, place S3 ON and switch power to ICE. The correct lighting sequence should be none, 2, 3, 4, 1, & 4, normal sequence every 5 seconds. (The LEDs are not in numerical order on the board. See the diagram on the next page for the location and numbering of LEDs). S3 should remain in the “OFF” position for normal operation.

21

Page 21
Image 21