![](/images/new-backgrounds/1069309/6930999x1.webp)
[e] KMD-900MWH
APPROXIMATE ICE | AMBIENT TEMP. |
|
| WATER TEMP. (ºF/ºC) |
|
| ||||||
PRODUCTION PER 24 HR. | (ºF/ºC) |
| 50/10 |
|
| 70/21 |
| 90/32 |
| |||
|
|
|
| 70/21 | 886 | 402 |
| 859 | 390 |
| 816 | 370 |
|
|
|
| 80/27 | 865 | 392 |
| 823 | 373 |
| 777 | 352 |
lbs./day |
| kg./day |
| 90/32 | 859 | 390 |
| 793 | 360 |
| 747 | 339 |
| 100/38 | 848 | 385 |
| 782 | 355 |
| 705 | 320 | |||
|
|
|
|
|
|
|
|
|
| |||
APPROXIMATE ELECTRIC | 70/21 |
| 1950 |
|
| 1950 |
| 1977 |
| |||
CONSUMPTION | 80/27 |
| 1950 |
|
| 1950 |
| 1992 |
| |||
|
|
|
| 90/32 |
| 1950 |
|
| 1950 |
| 1986 |
|
watts |
|
|
| 100/38 |
| 1965 |
|
| 1959 |
| 2020 |
|
APPROXIMATE WATER | 70/21 | 978 | 3.70 |
| 1023 | 3.87 |
| 1260 | 4.77 | |||
CONSUMPTION PER 24 HR. | 80/27 | 1013 | 3.83 |
| 1083 | 4.10 |
| 1417 | 5.36 | |||
|
|
|
| 90/32 | 1023 | 3.87 |
| 1132 | 4.28 |
| 1430 | 5.41 |
gal./day |
| m3/day | 100/38 | 1166 | 4.41 |
| 1202 | 4.55 |
| 1704 | 6.45 | |
FREEZING CYCLE TIME | 70/21 |
| 14 |
|
| 15 |
| 16 |
| |||
|
|
|
| 80/27 |
| 14 |
|
| 15 |
| 16 |
|
|
|
|
| 90/32 |
| 15 |
|
| 16 |
| 17 |
|
min. |
|
|
| 100/38 |
| 15 |
|
| 16 |
| 18 |
|
HARVEST CYCLE TIME | 70/21 |
| 3.2 |
|
| 3.0 |
| 2.5 |
| |||
|
|
|
| 80/27 |
| 3.0 |
|
| 2.7 |
| 2.4 |
|
|
|
|
| 90/32 |
| 3.0 |
|
| 2.4 |
| 2.3 |
|
min. |
|
|
| 100/38 |
| 2.7 |
|
| 2.4 |
| 2.2 |
|
HEAD PRESSURE | 70/21 | 275 | 19.3 |
| 276 | 19.4 |
| 285 | 20.0 | |||
|
|
|
| 80/27 | 276 | 19.4 |
| 277 | 19.5 |
| 290 | 20.4 |
|
|
|
| 90/32 | 276 | 19.4 |
| 278 | 19.5 |
| 289 | 20.4 |
PSIG | kg/cm2G | 100/38 | 280 | 19.7 |
| 281 | 19.7 |
| 300 | 21.1 | ||
SUCTION PRESSURE | 70/21 | 32 | 2.2 |
| 33 | 2.3 |
| 39 | 2.7 | |||
|
|
|
| 80/27 | 33 | 2.3 |
| 34 | 2.4 |
| 43 | 3.0 |
|
|
|
| 90/32 | 33 | 2.3 |
| 35 | 2.5 |
| 43 | 3.0 |
PSIG | kg/cm2G | 100/38 | 36 | 2.5 |
| 37 | 2.6 |
| 50 | 3.5 |
TOTAL HEAT OF REJECTION FROM CONDENSER | 13,480 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)] |
TOTAL HEAT OF REJECTION FROM COMPRESSOR | 2,440 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)] |
WATER FLOW FOR CONDENSER | 61 GAL./HR [AT 100oF (38oC) / WT 90oF (32oC)] |
PRESSURE DROP OF COOLING WATER LINE | LESS THAN 10 PSIG |
Note: Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold should be used for reference only.
We reserve the right to make changes in specifications and design without prior notice.
50