2)Defrost Timer

The defrost cycle starts when the float switch opens and completes the freeze cycle. But the defrost timer does not start counting until the thermistor senses 48°F at the evaporator outlet. The period from the end of the freeze cycle up to the point of the thermistor's sensing varies depending on the ambient and water temperatures.

3)High Temperature Safety - 127 ± 7°F

The temperature of the suction line in the refrigerant circuit is limited by the high temperature safety.

During the defrost cycle the evaporator temperature rises. The thermistor senses 48°F and starts the defrost timer. After the defrost timer counts down to zero, the normal freeze cycle begins. If the evaporator temperature continues to rise, the thermistor will sense the rise in temperature and at 127 ± 7°F the thermistor operates the high temperature safety.

This high temperature safety shuts down the circuit and the icemaker automatically stops. This high temperature safety protects the unit from excessive temperature. The control board will beep every 3 seconds. The white reset button on the control board must be pressed with power on to reset the safety.

4)Low Water Safety

If the pump motor is operated without water, the mechanical seal can fail. To prevent this type of failure, the controller board checks the position of the float switch at the end of the initial one minute water fill cycle and at the end of each defrost cycle.

If the float switch is in the up position (electrical circuit closed), the controller board changes to the ice making cycle. If the float switch is in the down position (electrical circuit open), the controller board changes to a one minute water fill cycle before starting the ice making cycle. This method allows for a low water safety shut down to protect the water pump from mechanical seal failure.

For water-cooled model, if the water is shut off, the unit is protected by the high pressure switch.

5)High Voltage Cutout

The maximum allowable supply voltage of this icemaker is limited by the high voltage cutout. If miswiring (especially on single phase 3 wire models) causes excessive voltage on the controller board, the high voltage cutout shuts down the circuit in 3 seconds and the icemaker automatically stops. When the proper supply voltage is resumed, the icemaker automatically starts running again. The control board will signal this problem using 7 beeps every 3 seconds.

6)LED Lights and Audible Alarm Safeties

The red LED indicates proper control voltage and will remain on unless a control voltage problem occurs. At startup a 5 second delay occurs while the board conducts an internal timer check. A short beep occurs when the power switch is turned ON or OFF.

20

Page 20
Image 20
Hoshizaki KMD-700MWH, KMD-900MAH, KMD-700MAH, KMD-700MRH, KMD-900MWH, KMD-900MRH service manual

KMD-900MRH, KMD-900MWH, KMD-700MRH, KMD-700MWH, KMD-700MAH specifications

The Hoshizaki KMD series offers a range of high-performance ice machines designed to meet the needs of various commercial applications, including restaurants, bars, and healthcare facilities. Models such as the KMD-700MAH, KMD-700MRH, KMD-900MRH, KMD-900MWH, and KMD-900MAH are equipped with innovative technologies and features that ensure efficient ice production and reliable operation.

The KMD-700MAH model is known for its adaptability and efficiency, producing flake ice that is ideal for use in various applications like food preservation, cooling drinks, and more. With a production capacity of up to 700 pounds of ice per day, this model is perfect for medium-sized establishments. Its advanced design incorporates a unique evaporator that enhances ice production while minimizing energy consumption.

Similarly, the KMD-700MRH offers versatility with a similar production capacity, focusing on reliability and performance. This model uses a high-efficiency compressor and a self-contained refrigeration system, ensuring consistent ice production across different ambient conditions. The KMD-700MRH is especially suitable for locations that require frequent and reliable ice replenishment.

The KMD-900 series takes performance a step further, with the KMD-900MRH and KMD-900MAH providing a higher production capacity of up to 900 pounds per day. These machines leverage Hoshizaki’s patented air-cooled technology, which enhances efficiency and reduces operating costs. The robust construction and advanced features make them ideal for high-demand environments.

The KMD-900MWH variant offers an innovative water-cooled option, suitable for businesses in areas with high ambient temperatures or those where air-cooled machines might struggle. By utilizing a water cooling system, it ensures stable performance even in challenging conditions, making it a dependable choice for busy kitchens.

All models in the KMD series feature an easy-to-use digital control panel, which allows for effortless monitoring and adjustments to operations. This technology not only simplifies management but also enables users to receive real-time alerts regarding machine status and maintenance needs, ultimately minimizing downtime.

In summary, the Hoshizaki KMD-700MAH, KMD-700MRH, KMD-900MRH, KMD-900MWH, and KMD-900MAH models are equipped with advanced ice-making technologies designed to deliver high production rates, efficient energy consumption, and reliable performance. Whether it's for a restaurant, bar, or healthcare application, these machines bring together reliability and versatility, making them indispensable tools for any commercial kitchen environment.