Hoshizaki KMD-700MRH, KMD-900MAH, KMD-700MAH, KMD-700MWH Removal and Replacement of Fan Motor

Models: KMD-900MRH KMD-900MWH KMD-700MRH KMD-700MWH KMD-700MAH KMD-900MAH

1 80
Download 80 pages 59.49 Kb
Page 69
Image 69

Min. 4-3/4"

Liquid Bypass

Flow

Fig. 3

10)Secure the insulation using the plastic cable ties.

11)Connect the thermistor leads through the bushing of the control box to the K3 connector on the controller board.

Note: Do not cut the leads of the thermistor while installing it.

12)Replace the control box cover and the panels in their correct positions.

13)Turn on the power supply.

12. Removal and Replacement of Fan Motor

Note: When replacing a fan motor with defective winding, it is recommended that a new capacitor be installed.

1)Turn off the power supply.

2)Remove the panels.

3)Remove the junction box cover from the remote condenser unit (remote air-cooled model).

4)Remove the closed end connectors from the fan motor leads.

5)Remove the fan motor bracket and fan motor.

6)Install the new fan motor, and replace the removed parts in the reverse order of which they were removed.

7)Replace the panels in their correct positions.

8)Replace the junction box cover in its correct position (remote air-cooled model).

9)Turn on the power supply.

69