KMD-901MAH

with Storage Bin

KMD-901MRH

 

Icemaker

Water Supply Icemaker

Inlet

1/2" FPT

Icemaker Water Supply Line Shut-Off Valve

Icemaker Water Supply Line Drain Valve

Icemaker

Drain Outlet

3/4" FPT

Bin

Bin Drain Outlet 3/4" FPT

Condensation Drain 5/8" OD Stainless Tube

Separate piping to approved drain. Leave a two-inch (5 cm) vertical air gap between the end of each pipe and the drain.

Two-inch (5 cm) air gap

KMD-901MWH

Icemaker

Water Supply

InletIcemaker

1/2" FPT

Condenser

Water Supply

Inlet

1/2" FPT

Condenser Bin

Drain Outlet

3/8" FPT

Icemaker

Drain Outlet

3/4" FPT

Bin Drain Outlet

3/4" FPT

Floor Drain

Icemaker Water Supply Line

Shut-Off Valve

Icemaker Water Supply Line

Drain Valve

Condenser Water Supply Line

Shut-Off Valve

Condenser Water Supply Line

Drain Valve

Condensation Drain

5/8" OD Stainless Tube

Separate piping to approved drain. Leave a two-inch (5 cm) vertical air

gap between the end of each pipe Fig. 9 and the drain.

18

Page 18
Image 18
Hoshizaki KMD-901MAH, KMD-901MWH instruction manual With Storage Bin, KMD-901MRH