I. Startup
CAUTION
1.All parts are
2.If the icemaker is turned off, wait for at least 3 minutes before restarting the icemaker to prevent damage to the compressor.
3.Do not operate the unit in the "WASH" position without water in the water tank. This will cause damage to the water pump seal.
1)Open the water supply line
2)Remove the front panel.
3)Move the control switch on the control box to the "ICE" position.
4)Replace the front panel in its correct position.
5)Turn on the power supply and allow the icemaker to operate for 5 minutes to fill up the water tank.
6)Remove the front panel and move the control switch to the "WASH" position. Replace the front panel in its correct position and allow the icemaker to run for 5 minutes.
7)Turn off the power supply, then remove the front panel.
8)Remove the insulation panel. Remove cube guide B, then remove cube guide A. Remove the overflow cap, overflow pipe, and water shield. Remove the drain plug and drain the water tank. See Fig. 10.
9)Replace all parts removed in step 8 in their correct positions. Be careful not to cross thread the drain plug or overflow pipe.
10)Clean the storage bin/dispenser unit liner using a neutral cleaner. Rinse thoroughly after cleaning.
11)Move the control switch to the "ICE" position and replace the front panel in its correct
position.
12)Turn on the power supply to start the automatic icemaking process.
Overflow Cap
Fig. 10 Overflow Pipe
Cube Guide A
Water Shield
Drain Plug
Cube Guide B
20