E. Electrical Connection

WARNING

1.Electrical connection must be made in accordance with the instructions on the "WARNING" tag, provided with the pig tail leads in the junction box.

2.Electrical connections must meet national, state, and local electrical code requirements. Failure to meet these code requirements could cause severe injury to individuals or extensive damage to equipment.

3.Be sure to install a proper ground to the icemaker.

Electrical connections must be installed in accordance with applicable national, state, and local regulations.

The icemaker requires an independent power supply. See the nameplate for proper voltage and breaker/fuse size.

The maximum allowable voltage variation is ±10 percent of the nameplate rating.

The white lead must be connected to the neutral conductor of the power source. Miswiring results in severe damage to the icemaker. See Fig. 3.

The opening for the power supply connection is 7/8" DIA to fit a 1/2" trade size conduit.

Usually an electrical permit and services of a licensed electrician are required.

WARNING

ELECTRICAL CONNECTION

The white lead must be connected to the neutral conductor of

the power source. Miswiring results in severe damage to the icemaker. (See Fig. below.)

Fig. 3

12

Page 12
Image 12
Hoshizaki KMD-901MAH, KMD-901MRH, KMD-901MWH instruction manual Electrical Connection