5. Electrical Connection

5. Electrical Connection

WARNING

1.Electrical connections must meet national, state, and local electrical code requirements. Failure to meet these code requirements could cause severe injury to individuals or extensive damage to equipment.

2.Be sure to install a proper ground from the icemaker to the remote condenser unit.

This remote condenser unit must be connected to the fan motor junction box on the icemaker.

The opening for the power supply connection is 7/8" DIA to fit a 1/2" trade size conduit.

Usually an electrical permit and services of a licensed electrician are required.

1)Remove the louver panel.

2)Remove the junction box cover on the remote condenser unit. Remove the fan motor junction box cover on the icemaker.

3)Install a ground wire from the icemaker to the remote condenser unit.

4)Connect the fan motor leads in the junction box of the remote condenser unit to the fan motor leads in the fan motor junction box of the icemaker.

5)Replace the junction box covers and the louver panel in their correct positions.

6.Stacking Remote Condenser Unit

1)Secure the lower remote condenser unit to the legs with eight bolts (not included).

2)Attach the upper remote condenser unit on the top of the lower.

3)Secure the upper remote condenser unit with the four screws provided.

4)Install refrigerant lines, and make electrical connection for each fan motor as shown earlier in this section.

Screw

Upper Remote

 

Condenser Unit

Screw

Screw

 

Lower Remote

Condenser Unit

Junction Box Cover

Louver Panel

Fig. 7

Fig. 8