Space for fixing

TECHNICAL DATA (Main Left Oven and Main Right Oven)

Oven

 

dimensions

37,0 x 38,0 x 44,8 cm

HxLxP

 

Volume

lt. 63

Voltage and

see data plate

frequency

 

Burners

may be adapted for use with any type

of gas shown on the data plate.

 

 

This appliance conforms to the following

 

European Economic Community

 

directives:

 

- 2006/95/EEC dated 12/12/06 (Low

 

Voltage) and subsequent amendments

 

- 2004/108/EEC dated 15/12/04

 

(Electromagnetic Compatibility) and

 

subsequent amendments

 

- 93/68/EEC dated 22/07/93 and

 

subsequent amendments.

 

- 2009/142/EEC dated 30/11/09 (Gas)

 

and subsequent amendments.

 

- 2012/19/EEC and subsequent

 

amendments.

The diagram below illustrates the minimum clearance

 

GB

between the cooker and adjacent walls, cupboards etc.

The wall behind the cooker, 50mm below and 450mm

 

 

above, and the width of the cooker, must be a non-

 

combustible material such as ceramic wall tiles.

 

If the cooker is to be fitted close to a corner on the left hand

 

side, ensure that there is a clearance of at least 50mm to

 

allow the main oven door to open fully for when removing

 

oven shelves.

 

Space for fixing

The cooker can be close fitted below hotplate level. This requires a minimum distance of 600mm between cupboard units of hotplate height.

When installing next to a tall cupboard, partition or wall, for

Cooker hoods

 

 

 

 

a minimum distance of 400mm above hotplate level, allow

If a cooker hood is to be installed, refer to the cooker hood

a side clearance of at least 65mm.

 

manufacturers’ instructions regarding fixing height.

 

Table 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Natural Gas

Burner

 

Diameter

 

Thermal Power

By-Pass

Nozzle

 

Flow*

 

 

(mm)

 

kW (p.c.s.*)

1/100

1/100

 

l/h

 

 

 

 

Nominal

Reduced

(mm)

(mm)

 

 

HOTPLATE - Semi Rapid - Front Left

75

 

1,90

0,40

35

102 Z

 

181

HOTPLATE - Rapid - Rear Left

100

 

3,00

0,70

44

116 Y

 

286

HOTPLATE - Wok Outer - Centre Front

130

 

4,10

1,50

63

110 x 2

 

390

HOTPLATE - Wok Inner - Centre Front

35

 

1,00

0,40

24

74

 

95

HOTPLATE - Auxiliary - Centre Rear

50

 

1,00

0,40

24

71 x

 

95

HOTPLATE - Double Face - Front Right

-

 

1,50

0,40

35

88 x

 

143

HOTPLATE - Double Face - Rear Right

-

 

1,50

0,40

35

88 x

 

143

GRILL

 

-

 

3,90

0,70

43

144

 

371

LEFT OVEN

 

-

 

2,60

0,45

34

123

 

248

RIGHT OVEN

 

-

 

2,60

0,45

34

123

 

248

Supply

 

 

Nominal (mbar)

 

20

 

Minimum (mbar)

 

17

Pressures

 

 

 

Maximum (mbar)

 

25

 

 

 

 

 

 

 

 

 

 

 

 

* At 15°C and 1013 mbar - dry gas

 

 

 

 

 

 

 

 

Methane

P.C.S. = 37.78 MJ/kg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEAT INPUT

 

 

 

 