HP 422690 I manual Allowable Pipe Length feet

Models: 422690 I

1 27
Download 27 pages 9.71 Kb
Page 10
Image 10

Table 2. Maximum Pipe Length --Non-Direct Vent

 

 

 

 

 

ALLOWABLE PIPE LENGTH (feet)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALTITUDE

FURNACE

 

PIPE

 

NUMBER OF SWEEP ELBOWS (SEE NOTE 1)

 

 

 

 

 

INPUT

 

DIA.

1

2

3

 

4

 

5

6

7

8

 

 

 

 

54,000

2"

112

108

104

 

100

 

96

92

88

84

 

 

 

 

72,000

2"

55

51

47

43

 

39

35

31

27

 

 

 

 

72,000

3"

150

150

150

150

 

150

150

150

150

 

 

 

0'-1000'

90,000

2"

36

32

28

24

 

20

16

-

-

 

 

 

 

90,000

3"

150

150

150

145

 

140

135

130

125

 

 

 

 

108,000

3"

85

80

75

70

 

65

60

55

50

 

 

 

 

126,000

3"

62

57

52

47

 

42

37

32

27

 

 

 

 

54,000

2"

97

93

90

86

 

83

80

76

73

 

 

 

 

72,000

2"

44

40

36

33

 

30

26

23

19

 

 

 

 

72,000

3"

150

150

150

150

 

150

150

150

150

 

 

 

1001'-2000'

90,000

2"

30

26

23

19

 

16

-

-

-

 

 

 

 

90,000

3"

140

135

130

125

 

120

115

110

105

 

 

 

 

108,000

3"

75

70

65

60

 

55

50

45

40

 

 

 

 

126,000

3"

50

45

40

35

 

30

25

20

15

 

 

 

 

54,000

2"

84

81

78

74

 

71

67

64

61

 

 

 

 

72,000

2"

37

34

30

27

 

24

21

18

15

 

 

 

2001'-3000'

72,000

3"

150

150

150

150

 

150

150

150

150

 

 

 

90,000

2"

24

21

18

14

 

11

-

-

-

 

 

 

 

90,000

3"

125

120

115

110

 

105

100

95

90

 

 

 

 

108,000

3"

50

45

40

35

 

30

25

20

15

 

 

 

 

126,000

3"

40

35

30

25

 

20

15

-

-

 

 

 

 

54,000

2"

71

68

64

61

 

58

55

51

48

 

 

 

 

72,000

2"

30

27

23

20

 

17

13

 

 

 

 

 

 

72,000

3"

150

150

150

150

 

150

150

150

150

 

 

 

3001'-4000'

90,000

2"

19

16

12

-

 

-

-

-

-

 

 

 

 

90,000

3"

100

95

90

85

 

80

75

70

65

 

 

 

 

108,000

3"

37

32

27

22

 

17

12

-

-

 

 

 

 

126,000

3"

30

25

20

15

 

10

-

-

-

 

 

 

 

126,000

 

3"

62

57

52

 

47

 

42

37

32

27

 

See Note 2

 

 

54,000

2"

57

54

50

 

47

 

44

40

36

33

 

 

 

 

72,000

2"

25

22

19

16

 

12

-

-

-

 

 

 

4001'-5000'

72,000

3"

150

150

150

150

 

150

150

150

150

 

 

 

90,000

3"

85

80

75

70

 

65

60

55

50

 

 

 

 

108,000

 

3"

85

80

75

 

70

 

65

60

55

50

 

See Note 2

 

 

126,000

 

3"

62

57

52

 

47

 

42

37

32

27

 

 

 

 

54,000

2"

43

40

37

 

33

 

30

27

24

20

 

 

 

 

72,000

2"

21

18

14

11

 

-

-

-

-

 

 

 

5001'-6000'

72,000

3"

150

150

150

150

 

150

150

150

150

 

 

 

90,000

3"

70

65

60

55

 

50

45

40

35

 

 

 

 

108,000

 

3"

85

80

75

 

70

 

65

60

55

50

 

See Note 2

 

 

126,000

 

3"

62

57

52

 

47

 

42

37

32

27

 

 

 

 

54,000

 

2"

110

106

104

 

100

 

96

92

88

84

 

 

 

 

72,000

 

2"

50

46

43

 

40

 

36

32

29

25

 

 

 

6001'-7000'

72,000

 

3"

150

150

150

 

150

 

150

150

150

150

 

See Note 2

 

90,000

 

3"

150

150

150

 

145

 

140

135

130

125

 

 

 

108,000

 

3"

85

80

75

 

70

 

65

60

55

50

 

 

 

 

126,000

 

3"

62

57

52

 

47

 

42

37

32

27

 

 

 

 

54,000

 

2"

97

93

90

 

86

 

83

80

76

73

 

 

 

 

72,000

 

2"

50

46

43

 

40

 

36

32

29

25

 

 

 

7001'-8000'

72,000

 

3"

150

150

150

 

150

 

150

150

150

150

 

See Note 2

 

90,000

 

3"

150

150

150

 

145

 

140

135

130

125

 

 

 

108,000

 

3"

85

80

75

 

70

 

65

60

55

50

 

 

 

 

126,000

 

3"

60

55

50

 

45

 

40

35

30

25

 

 

 

 

54,000

 

2"

84

81

78

 

74

 

71

67

64

61

 

 

 

 

72,000

 

2"

41

38

34

 

31

 

28

24

21

17

 

 

 

8001'-9000'

72,000

 

3"

150

150

150

 

150

 

150

150

150

150

 

See Note 2

 

90,000

 

3"

150

150

150

 

145

 

140

135

130

125

 

 

 

108,000

 

3"

70

65

60

 

55

 

50

45

40

35

 

 

 

 

126,000

 

3"

45

40

35

 

30

 

25

20

15

 

 

 

 

 

54,000

 

2"

71

68

64

 

61

 

58

55

51

48

 

 

 

 

72,000

 

2"

35

31

28

 

25

 

21

18

15

-

 

 

 

9001'-10000'

72,000

 

3"

150

150

150

 

150

 

150

150

150

150

 

See Note 2

 

90,000

 

3"

150

150

150

 

145

 

140

135

130

125

 

 

 

108,000

 

3"

55

50

45

 

40

 

35

30

25

20

 

 

 

 

126,000

 

3"

35

30

25

 

20

 

15

10

-

-

 

 

NOTE 1: The table assumes the use of sweep elbows. If using hard 90? elbows, the vent length should be decreased an additional 3 feet for every elbow used.

NOTE 2: The shaded portions of the table require the high altitude pressure switch in order to operate the furnace at the listed vent lengths.

Page 10

Installer’s Information Manual

Page 10
Image 10
HP 422690 I manual Allowable Pipe Length feet