Catalyst Stack System Configuration View

Attach Type

This button allows you to change the attachment type of the FDDI connection to the device. Table 3-1shows the possible attachment types. New attach type settings will not take effect until the concentrator is reset.

Table 3-1. Possible Attach Types

Attach Type

Definition

 

 

Other

None of the following.

 

 

DualAttach

The first FDDI port is configured as an A port,

 

the second as a B port.

 

 

SingleAttach

The first FDDI port is configured as an S port,

 

the second as an M port.

 

 

NullAttach

The first two FDDI ports are configured as M

 

ports.

 

 

Insert Mode

This button allows you to select the mode for inserting M-ports into the concentrator ring. Possible insertion modes are: Other (none of the following), Standard, Scheduled, and Graceful.

Reset

This button allows you to initiate a reset of the control logic of all modules in the device. The default is Other.

Traffic

Displays the value of the traffic meter, shown as a percentage of bandwidth utilization on the network for the previous polling interval.

Enable Redirects

Allows you to select whether the device is able to send or receive ICMP redirect messages.

Enable Modem

Allows you to select whether this device’s RS-232 port modem control lines are enabled or disabled.

Enable Rmon

Allows you to select whether this SNMP agent supports the RMON MIB.

9032208 E4

Configuration Views

 

3-5