Installing a 5120 EI switch in a 19-inch rack

You can install a 5120 EI switch in a 19-inch standard rack by using different mounting positions. Table 6 shows the installation methods available for the switches of different depths.

Table 6 Installation methods

 

 

Use front

Use front mounting

Use front and

Chassis

Depth

mounting

brackets and a rack

rear mounting

brackets

 

 

shelf

brackets

 

 

only

 

 

 

 

5120-24G EI (2 slots)

5120-24G EI TAA (2 slots)

5120-48G EI (2 slots)

5120-48G EI TAA (2 slots)

5120-24G EI

5120-48G EI

 

Yes (see

 

Rack-mounti

300 mm

ng by using

(11.81 in)

only front

 

mounting

 

brackets

Yes (see

Rack-mounting by

using front mounting No brackets and a rack shelf”)

5120-24G-PoE+ EI (2 slots)

5120-24G-PoE+ EI TAA (2 slots)

5120-48G-PoE+ EI (2 slots)

5120-48G-PoE+ EI TAA (2 slots)

420 mm

No

(16.54 in)

 

Yes (see

Rack-mounting by using front mounting brackets and a rack shelf”)

Yes (see

Rack-mounting by using front and rear mounting brackets”)

NOTE:

For a switch with a 420 mm (16.54 in) of depth, the front mounting brackets are not weight-bearing.

Mounting brackets

Figure 30 Front mounting bracket

1

2

(1)Hole for attaching to a rack (by using an M6 screw)

(2)Hole for attaching to the switch chassis

17

Page 22
Image 22
HP 5120 SI, 5120 48G manual Installing a 5120 EI switch in a 19-inch rack, Mounting brackets, Installation methods