Technical Data
Technical Data
Maximum Working Fluid Pressure | 100 psi (0.7 | MPa, 7 bar) |
Maximum Working Air Pressure | 100 psi (0.7 | MPa, 7 bar) |
Maximum HVLP Inbound Air Pressure | 35 psi (25 kPa, 2.5 bar) | |
Maximum Compliant Gun Inlet Pressure | 30 psi (21 kPa, 2.1 bar) | |
Maximum Working Fluid Temperature | 120° F (49° C) | |
Minimum Air Cylinder Actuation Pressure | 50 psi (0.34 | MPa, 3.4 bar) |
Weight | 1.5 lbs (992 g) | |
Wetted Parts | Stainless Steel, Ultra High Molecular Weight Polyethyl- | |
| ene, Chemically Resistant Fluoroelastomer, Acetal, | |
| PTFE, PEEK |
Loctite® is a registered trademark of the Loctite Corporation.
Triggering Speed
These values apply to a new gun with a 12 ft. (3.6 m), 1/4 in. (6.3 mm) OD cylinder air line and a 0.055 in. nozzle. These values will vary slightly with use and with variations in equipment.
Cylinder Air Pressure | Fluid Pressure | Air Pressure |
|
|
psi (kPa, bar) | psi (kPa, bar) | psi (kPa, bar) | msec to fully open | msec to fully close |
|
|
|
|
|
50 (0.35, 3.5) | 50 (0.35, 3.5) | 100 (0.7, 7.0) | 58.4 | 50.4 |
|
|
|
|
|
Sound Data (dBa)
|
| Atomizing Air |
|
|
| |
Air Cap | Nozzle Part No. | Pressure | Fan Air Pressure | Sound Pressure | Sound Power | |
Part No. | and Size | psi (kPa, bar) | psi (kPa, bar | dB(A)† | dB(A)‡ | |
|
|
|
|
|
| |
288134 | 234744, 0.055 in. | 35 (250, 2.5) | 35 (250, 2.5) | 85.9 | 86.7 | |
100 (0.7, 7.0) | 100 (0.7, 7.0) | 97 | 92.8 | |||
|
| |||||
|
|
|
|
|
|
†Sound pressure measured 3.28 ft. (1 m) from equipment.
‡ Sound power measured per ISO
311051D | 37 |