Step

 

Command

Remarks

 

 

 

The default is 1.

6. Specify the number of stop bits.

stopbits { 1 1.5 2 }

Stop bits indicate the end of a

 

 

 

character. The more the bits, the

 

 

 

slower the transmission.

 

 

 

 

 

 

 

By default, the number of data bits

 

 

 

in each character is 8.

7.

Specify the number of data bits

 

The setting depends on the

databits { 5 6 7 8 }

character coding type. For

 

in each character.

 

example, you can set it to 7 if

 

 

 

 

 

 

 

 

standard ASCII characters are to

 

 

 

be sent, and set it to 8 if extended

 

 

 

ASCII characters are to be sent.

 

 

 

 

8.

Define a shortcut key for

activation-key character

By default, press Enter to start a

 

starting a session.

session.

 

 

 

 

 

 

9.

Define a shortcut key for

escape-key { default character }

By default, press Ctrl+C to

 

terminating tasks.

terminate a task.

 

 

 

 

 

 

 

 

 

By default, the terminal display

 

 

 

type is ANSI.

 

 

 

The device supports two types of

 

 

 

terminal display: ANSI and

 

 

 

VT100. HP recommends setting the

 

 

 

display type of both the device and

10. Configure the type of terminal

 

the client to VT100. If the device

terminal type { ansi vt100 }

and the client use different display

 

display.

 

types (for example, HyperTerminal

 

 

 

 

 

 

 

 

or Telnet terminal) or both are set to

 

 

 

ANSI, when the total number of

 

 

 

characters of the currently edited

 

 

 

command line exceeds 80, an

 

 

 

anomaly such as cursor corruption

 

 

 

or abnormal display of the terminal

 

 

 

display might occur on the client.

 

 

 

 

11.

Configure the user privilege

user privilege level level

By default, the default command

 

level for login users.

level is 0 for the AUX user interface.

 

 

 

 

 

 

12. Set the maximum number of

 

By default, a screen displays 24

 

lines at most.

 

lines to be displayed on a

screen-length screen-length

 

A value of 0 disables pausing

 

screen.

 

 

 

 

between screens of output.

13.

Set the size of command

history-command max-size value

By default, the buffer saves 10

 

history buffer.

history commands at most.

 

 

 

 

 

 

 

 

 

The default idle-timeout is 10

 

 

 

minutes. The system automatically

 

 

 

terminates the user's connection if

14.

Set the idle-timeout timer.

idle-timeout minutes [ seconds ]

there is no information interaction

between the device and the user in timeout time.

Setting idle-timeout to 0 disables the timer.

45