Code

Meaning

Comments

 

Action:

When operating the drive in this type of environment, the

 

 

following actions should occur:

 

 

1. The calling application receiving this code should

 

 

issue a MODE SENSE command requesting the drive

 

 

to return all parameters.

 

 

2. The application should check those parameters over

 

 

which it has configuration control, to ensure that the

 

 

current configuration of the drive does not conflict

 

 

with what the application expects.

 

 

3. If it finds discrepancies, the application can either

 

 

reconfigure the drive to the original values, or halt

 

 

and report an error.

 

 

4. If an error is reported, a console message must be

 

 

displayed, and information logged to the system log.

 

 

 

2A 02

Log parameters changed

The Log parameters for the drive have been changed by

 

 

an initiator other than the one issuing the command.

 

 

 

2A 03

Reservations pre-empted

A PERSISTENT RESERVE OUT command with the Clear

 

 

service action removed all reservations and the persistent

 

 

reservation.

 

 

 

2A 04

Reservations released

A PERSISTENT RESERVE OUT command executed. The

 

 

original persistent reservation has been replaced with

 

 

another of a different type or removed completely.

 

 

 

2A 05

Registrations pre-empted

A PERSISTENT RESERVE OUT command was executed

 

 

which removed all registrations.

 

 

 

2A 11

Data encryption parameters

The encryption parameters that this initiator was using

 

changed by another

have been modified by another initiator.

 

initiator

 

 

 

 

2A 12

Data encryption parameters

The encryption parameters that this initiator was using

 

changed by vendor specific

have been modified because of a vendor specific event

 

event

(such as tape unload or reservation released).

 

 

 

3F 01

Firmware upgraded

The firmware in the drive has just been changed by a

 

 

WRITE BUFFER or MAINTENANCE OUT command,

 

 

Firmware Update Cartridge, ADI or ACI.

 

 

 

3F 05

Device identifier changed

A SET DEVICE IDENTIFIER command has been successful.

 

 

 

3F 0E

Reported LUNs data has

 

 

changed

 

 

 

 

HP LTO Ultrium 4 drives technical reference manual, volume 2: software integration 71 HP restricted

Page 71
Image 71
HP LTO 4 SAS Action, service action removed all reservations and the persistent, WRITE BUFFER or MAINTENANCE OUT command