Flags

The following table lists the flags that could potentially be supported in tape drives. Of these, flags 3,4,5,6,20,22 and 31 are mandatory for drives such as Ultrium drives that support cleaning cartridges.

The flags are grouped into the following sections:

Flags 1 to 19: For tape drive write/read management

Flags 20 to 25: For cleaning management

Flags 26 to 39: For tape drive hardware errors

Flags 50 to 60: For additional tape drive errors

For each flag, the message that the host software should display to the user is given, together with the cause of the flag being set. The Type column classifies the flags by seriousness into the following three groups:

I

Information

A suggestion to the user.

W

Warning

The user is advised to take action. Performance or data

 

 

may be at risk otherwise.

 

 

 

C

Critical!

Take action immediately.

The Set column indicates if the flag can be set by LTO 4 drives. The other flags are supported but never set.

 

Flag

Type

Set

Recommended Host Message

Cause

Flags for Tape Drive Write/Read Management

 

1

Read warning

W



The tape drive is having problems

The drive is having severe

 

 

 

 

reading data. No data has been lost,

trouble reading.

 

 

 

 

but there has been a reduction in the

 

 

 

 

 

capacity of the tape.

 

 

 

 

 

 

 

2

Write warning

W

 

The tape drive is having problems

The drive is having severe

 

 

 

 

writing data. No data has been lost,

trouble writing.

 

 

 

 

but there has been a reduction in the

 

 

 

 

 

capacity of the tape.

 

 

 

 

 

 

 

3

Hard error

W



The operation has stopped because

This flag is set for any

 

 

 

 

an error has occurred while reading

unrecoverable

 

 

 

 

or writing data which the drive

read/write/positioning

 

 

 

 

cannot correct.

error, and is cleared

 

 

 

 

 

internally when the tape is

 

 

 

 

 

ejected. The flag is set as an

 

 

 

 

 

explanation of the error in

 

 

 

 

 

conjunction with one of the

 

 

 

 

 

recovery action flags 4, 5,

 

 

 

 

 

or 6.

 

 

 

 

 

 

HP LTO Ultrium 4 drives technical reference manual, volume 2: software integration 79 HP restricted

Page 79
Image 79
HP LTO 4 SCSI, LTO 4 FC, LTO 4 SAS manual Flags, Type