Flag

Type

Set

Recommended Host Message

Cause

57

Automation

C

 

The tape drive has a problem with

The drive has identified a

 

interface failure

 

 

the automation interface:

fault in the automation

 

 

 

 

1.

Check the power to the

interface.

 

 

 

 

 

 

 

 

 

 

automation system.

 

 

 

 

 

2.

Check the cables and cable

 

 

 

 

 

 

connections.

 

 

 

 

 

3.

Call the supplier’s helpline if the

 

 

 

 

 

 

problem persists.

 

 

 

 

 

 

 

58

Firmware failure

W



The tape drive has reset itself due to

There is a firmware bug.

 

 

 

 

a detected firmware fault. If the

 

 

 

 

 

problem persists, call the supplier’s

 

 

 

 

 

helpline.

 

 

 

 

 

 

 

59

WORM

W



The tape drive has detected an

Someone has tampered with

 

medium—integr

 

 

inconsistency while checking the

the WORM tape.

 

ity check failed

 

 

WORM tape for integrity. Someone

 

 

 

 

 

may have tampered with the

 

 

 

 

 

cartridge.

 

 

 

 

 

 

 

60

WORM

W



An attempt has been made to

The application software

 

medium—

 

 

overwrite user data on a WORM

does not recognize the tape

 

overwrite

 

 

tape:

as WORM.

 

attempted

 

 

1.

If you used a WORM tape

 

 

 

 

 

 

 

 

 

 

 

inadvertently, replace it with a

 

 

 

 

 

 

normal data tape.

 

 

 

 

 

2.

If you used a WORM tape

 

 

 

 

 

 

intentionally, check that:

 

 

 

 

 

the software application is

 

 

 

 

 

 

compatible with the WORM tape

 

 

 

 

 

 

format you are using.

 

 

 

 

 

the cartridge is bar-coded

 

 

 

 

 

 

correctly for WORM.

 

 

 

 

 

 

 

 

 

 

 

Flags 61–64 are not currently used

 

Note that often messages will not appear in isolation. For example, message 01h (“The tape drive is having problems reading data.”) is likely to appear with a message suggesting remedial action, such as message 04h (“You are advised to copy any data...”) or message 14h (Clean Now).

Each flag is cleared to zero in the following circumstances:

At power-on.

When specified corrective action has been taken, such as using a cleaning cartridge.

When the TapeAlert Log page is read.