HP LTO 4 SAS One-Button Disaster Recovery OBDR, Responding to the ‘Clean’ LED, Supporting OBDR

Models: LTO 4 SCSI

1 96
Download 96 pages 24.92 Kb
Page 89
Image 89
One-Button Disaster Recovery (OBDR)

5.Optionally, automate the recommended recovery actions if there are multiple tape drives or autoloaders present.

For example, the application could perform a cleaning cycle in response to flags 20 (Clean Now) and 21 (Clean Periodic). It could perform a tape copy for flags 4 (Media performance degraded) and 7 (Media life expired), and then retire the suspect tape cartridge.

This provides an opportunity for applications to add value to the TapeAlert capability of the drives.

Supporting OBDR NOTE: An application must not fail a backup job as a result of TapeAlert information. It should use the information as a preventative measure, taking action to avoid failure, or encouraging the user to take action. It should also retain the log information to help in diagnosis if a job does eventually fail.

One-Button Disaster Recovery (OBDR)

Responding to the ‘Clean’ LED NOTE: FC drives and drives in libraries do not support OBDR.

All HP Ultrium parallel-SCSI products support HP’s One-Button Disaster Recovery (OBDR) technology. This provides the fastest possible, one-step approach to regenerating a single server without using additional floppy disks or CD-ROMs.

For a general overview, see “OBDR and CD-ROM Emulation” in Chapter 1, “Ultrium Features”, of Background to Ultrium Drives, Volume 6 of the HP Ultrium Technical Manual. For details of the SCSI implementation, see “CD-ROM Emulation” in Chapter 1, “Interface Implementation”, of SCSI Interface, Volume 3 of the HP Ultrium Technical Manual.

For details of how to use OBDR see the appropriate User’s Guide.

To identify whether the firmware supports OBDR, look for the string $DR-10 in bytes 43–48 of the Inquiry data.

Supporting OBDR

The OBDR implementation in HP Ultrium drives is functionally identical to that in DAT/DDS, so no additional design or coding should be required in order to support it. The only effort needed should be in software testing.

Responding to the ‘Clean’ LED

Manual background NOTE: HP recommends that software applications use the TapeAlert log, which should mean that potential tape or cleaning problems are flagged and corrected before the drive ever reaches the point of displaying the ‘Clean’ LED.

If during normal operation, the drive detects an excessive number of RWW retries, the ‘Clean’ LED is lit. If this happens, a user should follow this procedure:

HP LTO Ultrium 4 drives technical reference manual, volume 2: software integration 89 HP restricted

Page 89
Image 89
HP LTO 4 SAS, LTO 4 FC, LTO 4 SCSI manual One-Button Disaster Recovery OBDR, Responding to the ‘Clean’ LED, Supporting OBDR